Figure 3-7 Installing the AI-485 adaptor to the drive
2
1
3
1. Identify the two plastic fingers on the underside of the AI-485 adaptor (1) - then insert the two fingers into the corresponding slots in the spring
loaded sliding cover on the top of the drive.
2. Hold the adaptor firmly and push the spring loaded protective cover towards the back of the drive to expose the connector block (2) below.
3. Press the adaptor downwards (3) until the adaptor connector locates into the drive connection below.
Figure 3-8 Removal of the AI-485 adaptor
1
* To remove the AI-485 adaptor, pull it up and away from the drive in the direction shown (1)