Parameter
12.001 Threshold Detector 1 Output
12.002 Threshold Detector 2 Output
12.003 Threshold Detector 1 Source
12.004 Threshold Detector 1 Level
12.005 Threshold Detector 1 Hysteresis
12.006 Threshold Detector 1 Output Invert
12.007 Threshold Detector 1 Destination
12.008 Variable Selector 1 Source 1
12.009 Variable Selector 1 Source 2
12.010 Variable Selector 1 Mode
12.011 Variable Selector 1 Destination
12.012 Variable Selector 1 Output
12.013 Variable Selector 1 Source 1 Scaling
12.014 Variable Selector 1 Source 2 Scaling
12.015 Variable Selector 1 Control
12.016 Variable Selector 1 Enable
12.023 Threshold Detector 2 Source
12.024 Threshold Detector 2 Level
12.025 Threshold Detector 2 Hysteresis
12.026 Threshold Detector 2 Output Invert
12.027 Threshold Detector 2 Destination
12.028 Variable Selector 2 Source 1
12.029 Variable Selector 2 Source 2
12.030 Variable Selector 2 Mode
12.031 Variable Selector 2 Destination
12.032 Variable Selector 2 Output
12.033 Variable Selector 2 Source 1 Scaling
12.034 Variable Selector 2 Source 2 Scaling
12.035 Variable Selector 2 Control
12.036 Variable Selector 2 Enable
12.040 BC Brake Release
12.041 BC Enable
12.042 BC Upper Current Threshold
12.043 BC Lower Current Threshold
12.044 BC Brake Release Frequency
12.045 BC Brake Apply Frequency
12.046 BC Brake Delay
12.047 BC Post-brake Release Delay
12.050 BC Initial Direction
BC Brake Apply Through Zero Thres
12.051
hold
RW
Read / Write RO
Read-only
Character
Chr
Bin
Binary parameter
parameter
Number
Num
DE
Destination
parameter
FI
Filtered
US
User save
Unidrive M400 User Guide
Issue Number: 2
Electrical
Getting
Basic
Running
installation
started
parameters
the motor
Range ( )
OL
Off (0) or On (1)
Off (0) or On (1)
0.000 to 30.999
0.00 to 100.00 %
0.00 to 25.00 %
Off (0) or On (1)
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
Input 1 (0), Input 2 (1), Add (2),
Subtract (3), Multiply (4), Divide (5),
Time Const (6), Ramp (7),
Modulus (8), Powers (9)
0.000 to 30.999
±100.00 %
±4.000
±4.000
0.00 to 100.00
Off (0) or On (1)
0.000 to 30.999
0.00 to 100.00 %
0.00 to 25.00 %
Off (0) or On (1)
0.000 to 30.999
0.000 to 30.999
0.000 to 30.999
Input 1 (0), Input 2 (1), Add (2),
Subtract (3), Multiply (4), Divide (5),
Time Const (6), Ramp (7),
Modulus (8), Powers (9)
0.000 to 30.999
±100.00 %
±4.000
±4.000
0.00 to 100.00
Off (0) or On (1)
Off (0) or On (1)
Disable (0), Relay (1), Digital IO (2),
User (3)
0 to 200 %
0 to 200 %
0.00 to 20.00 Hz
0.00 to 20.00 Hz
0.0 to 25.0 s
0.0 to 25.0 s
Ref (0), Forward (1), Reverse (2)
0.00 to 25.00 Hz
Bit
Bit parameter
IP
IP address
No
ND
default value
Power-
PS
down save
NV Media Card
Onboard
Optimization
Operation
PLC
Default ( )
RFC-A
OL
0.000
0.00 %
0.00 %
Off (0)
0.000
0.000
0.000
Input 1 (0)
0.000
1.000
1.000
0.00
On (1)
0.000
0.00 %
0.00 %
Off (0)
0.000
0.000
0.000
Input 1 (0)
0.000
1.000
1.000
0.00
On (1)
Disable (0)
50 %
10 %
1.00 Hz
2.00 Hz
1.0 s
1.0 s
Ref (0)
0.00 Hz
Txt
Text string
Date Date parameter
Mac MAC address
Ver
Version number SMP
Rating
RA
NC
Non-copyable
dependent
Advanced
Technical data Diagnostics
parameters
Type
RFC-A
RO
Bit
ND NC PT
RO
Bit
ND NC PT
RW
Num
RW
Num
RW
Num
RW
Bit
RW
Num
DE
RW
Num
RW
Num
RW
Txt
RW
Num
DE
RO
Num ND NC PT
RW
Num
RW
Num
RW
Num
RW
Bit
RW
Num
RW
Num
RW
Num
RW
Bit
RW
Num
DE
RW
Num
RW
Num
RW
Txt
RW
Num
DE
RO
Num ND NC PT
RW
Num
RW
Num
RW
Num
RW
Bit
RO
Bit
ND NC PT
RW
Txt
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Num
RW
Txt
RW
Num
Time
Time parameter
Slot, menu,
parameter
PT
Protected
UL listing
information
PT
US
US
US
US
PT
US
PT
US
PT
US
US
PT
US
US
US
US
US
PT
US
US
US
US
PT
US
PT
US
PT
US
US
PT
US
US
US
US
US
US
US
US
US
US
US
US
US
US
147

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents