Basic Parameters; Menu 0: Basic Parameters - Emerson Unidrive M400 User Manual

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M400:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
6

Basic parameters

Menu 0 is used to bring together various commonly used parameters for basic easy set up of the drive. All the parameters in Menu 0 appear in other
menus in the drive (denoted by {...}). Menus 22 can be used to configure the parameters in Menu 0.
6.1

Menu 0: Basic parameters

Parameter
00.001 Minimum Reference Clamp
Maximum Reference
00.002
Clamp
00.003 Acceleration Rate 1
00.004 Deceleration Rate 1
00.005 Drive Configuration
00.006 Motor Rated Current
00.007 Motor Rated Speed
00.008 Motor Rated Voltage
00.009 Motor Rated Power Factor
00.010 User Security Status
00.012 Input Logic Polarity
00.015 Jog Reference
00.016 Analog Input 1 Mode
00.017 Bipolar Reference Enable
00.018 Preset Reference 1
00.025 User Security Code
Power-up Keypad Control
00.027
Mode Reference
00.028 Ramp Mode Select
00.029 Ramp Enable
00.030 Parameter Cloning
00.031 Stop Mode
Dynamic V to F Select /
00.032
Flux Optimization Select
66
Electrical
Getting
Basic
Running
installation
started
parameters
the motor
Range( )
OL
±VM_NEGATIVE_REF_CLAMP Hz
±VM_POSITIVE_REF_CLAMP Hz
±VM_ACCEL_RATE s
±VM_ACCEL_RATE s
AV (0), AI (1), AV Preset (2), AI Preset (3), Preset (4),
Keypad (5), Keypad Ref (6), Electronic Pot (7), Torque
Control (8), Pid Control (9)
±VM_RATED_CURRENT A
0.0 to 80000.0 rpm
±VM_RATED_VOLTAGE V
0.00 to 1.00
Menu 0 (0), All Menus (1),
Read only Menu 0 (2), Read only (3),
Status Only (4), No Access (5)
Negative Logic (0) or Positive Logic (1)
0.00 to 300.00 Hz
4-20 mA Stop (-6), 20-4 mA Stop (-5),
4-20 mA Low (-4), 20-4 mA Low (-3),
4-20 mA Hold (-2), 20-4 mA Hold (-1),
0-20 mA (0), 20-0 mA (1), 4-20 mA Trp (2),
20-4 mA Trp (3), 4-20 mA (4),
20-4 mA (5), Voltage (6)
Off (0) or On (1)
±VM_SPEED_FREQ_REF Hz
0 to 9999
Reset (0), Last (1), Preset (2)
Fast (0), Standard (1), Std boost (2),
Fast boost (3)
None (0), Read (1), Program (2),
Auto (3), Boot (4)
Coast (0), Ramp (1), Ramp dc I (2), dc I (3), Timed dc I
(4), Disable (5), No Ramp (6)
0 to 1
NV Media Card
Onboard
Optimization
Operation
PLC
Default( )
RFC-A
OL
50Hz default: 50.00 Hz
60Hz default: 60.00 Hz
Maximum Heavy Duty
50Hz
default:
1500.0 rpm
60Hz
default:
1800.0 rpm
110V drive: 230 V
200V drive: 230 V
400V drive 50 Hz: 400 V
400V drive 60 Hz: 460 V
575V drive: 575 V
690V drive: 690 V
Menu 0 (0)
Positive Logic (1)
Voltage (6)
Standard (1)
Off (0) or On (1)
Advanced
Technical data Diagnostics
parameters
RFC-A
0.00 Hz
RW Num
RW Num
5.0 s
RW Num
10.0 s
RW Num
AV (0)
RW
Txt
Rating
RW Num
(11.032) A
50Hz
default:
1450.0 rpm
RW Num
60Hz
default:
1750.0 rpm
RW Num
0.85
RW Num
RW
Txt
ND NC PT
RW
Txt
1.50 Hz
RW Num
RW
Txt
Off (0)
RW
Bit
0.00 Hz
RW Num
0
RW Num ND NC PT US
Reset (0)
RW
Txt
RW
Txt
On (1)
RW
Bit
None (0)
RW
Txt
Ramp (1)
RW
Txt
0
RW Num
Unidrive M400 User Guide
UL listing
information
Type
US
US
US
US
PT US
RA
US
US
RA
US
RA
US
US
US
US
US
US
US
US
US
NC
US
US
US
Issue Number: 2

Hide quick links:

Advertisement

Table of Contents
loading