Figure 11-12 Menu 8 Logic Diagram
T15 Digital Input 6
08.010
I/O Input
Logic Polarity
T16 Digital Input 7
08.010
I/O Input
Logic Polarity
128
Electrical
Getting
Basic
Running
installation
started
parameters
the motor
T15 Digital
Input 6 State
08.006
0
1
2
Frequency Input (menu 3)
Encoder AB (menu 3)
T16 Digital
Input 7 State
08.007
0
1
2
NV Media Card
Optimization
Operation
T15 Digital
Input 6 Invert
08.016
x(-1)
T16 Digital
Input 7 Invert
08.017
x(-1)
Encoder AB (menu 3)
X
X
The parameters are all shown in their default settings
Onboard
Advanced
Technical data Diagnostics
PLC
parameters
T15 Digital input
6 control
08.086
T15 Digital input
6 destination B
08.126
T15 Digital input
1
6 destination A
08.026
Any unprotected
bit parameter
??.???
??.???
T16 Digital input
7 control
08.087
T16 Digital input
7 destination B
08.127
T16 Digital input
1
7 destination A
08.027
Any unprotected
bit parameter
??.???
??.???
Key
Input
X
Read-write (RW)
mm.ppp
terminals
parameter
Read-only (RO)
X
Output
mm.ppp
parameter
terminals
Unidrive M400 User Guide
UL listing
information
Jog forward
06.031
00.000
Issue Number: 2