Optional External Emc Filters - Emerson Unidrive M400 User Manual

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M400:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Emission
The drive contains an in-built filter for basic emission control. An
additional optional external filter provides further reduction of emission.
The requirements of the following standards are met, depending on the
motor cable length and switching frequency.
Table 12-26 Size 1 emission compliance (200 V drives)
Motor cable
length (m)
3
Using internal filter:
0 – 2
Using internal filter and external ferrite ring (1 turn):
0 – 10
10 - 20
Using external filter:
0 – 20
20 - 100
Table 12-27 Size 1 emission compliance (400 V drives)
Switching frequency (kHz)
Motor cable
length (m)
3
4
Using internal filter:
0 – 5
Using internal filter and external ferrite ring (2 turns):
0 – 10
Using external filter:
0 – 20
20 - 100
Key (shown in decreasing order of permitted emission level):
E2R
EN 61800-3:2004 second environment, restricted distribution
(Additional measures may be required to prevent interference)
E2U
EN 61800-3:2004 second environment, unrestricted distribution
I
Industrial generic standard EN 61000-6-4:2007
EN 61800-3:2004 first environment restricted distribution (The
following caution is required by EN 61800-3:2004)
This is a product of the restricted distribution class according
to IEC 61800-3. In a residential environment this product may
cause radio interference in which case the user may be
required to take adequate measures.
CAUTION
R
Residential generic standard EN 61000-6-3:2007
EN 61800-3:2004 first environment unrestricted distribution
EN 61800-3:2004 defines the following:
The first environment is one that includes residential premises. It
also includes establishments directly connected without intermediate
transformers to a low-voltage power supply network which supplies
buildings used for residential purposes. The second environment is
one that includes all establishments other than those directly
connected to a low-voltage power supply network which supplies
buildings used for residential purposes.
Restricted distribution is defined as a mode of sales distribution in
which the manufacturer restricts the supply of equipment to
suppliers, customers or users who separately or jointly have
technical competence in the EMC requirements of the application of
drives.
IEC 61800-3:2004 and EN 61800-3:2004
The 2004 revision of the standard uses different terminology to align the
requirements of the standard better with the EC EMC Directive.
170
Electrical
Getting
Basic
installation
started
parameters
the motor
Switching frequency (kHz)
4
6
8
12
6
8
12
Running
NV Media Card
Optimization
Operation
Power drive systems are categorized C1 to C4:
Category
Intended for use in the first or second
C1
environments
Not a plug-in or movable device, and
16
intended for use in the first environment
C2
only when installed by a professional, or
in the second environment
Intended for use in the second
C3
environment, not the first environment
Rated at over 1000 V or over 400 A,
C4
intended for use in complex systems in
the second environment
Note that category 4 is more restrictive than E2R, since the rated current
of the PDS must exceed 400 A or the supply voltage exceed 1000 V, for
the complete PDS.
12.2

Optional external EMC filters

16
Table 12-28 EMC filter cross reference
Model
200 V
400 V
Onboard
Advanced
Technical
PLC
parameters
data
Definition
CT Part number
Unidrive M400 User Guide
UL listing
Diagnostics
information
Corresponding
code used
above
R
I
E2U
E2R
Issue Number: 2