Basic parameters (Menu 0)

Menu 0 is used to bring together various commonly used parameters for basic easy set up of the
drive. All the parameters in Menu 0 appear in other menus in the drive (denoted by {...}). Menus 22
can be used to configure the parameters in Menu 0.
6.1

Menu 0: Basic parameters

Parameter
Minimum Reference
00.001
Clamp
Maximum Reference
00.002
Clamp
00.003 Acceleration Rate 1
00.004 Deceleration Rate 1
00.005 Drive Configuration
00.006 Motor Rated Current
00.007 Motor Rated Speed
00.008 Motor Rated Voltage
Motor Rated Power
00.009
Factor
00.010 User Security Status
00.015 Jog Reference
00.016 Analog Input 1 Mode
Bipolar Reference
00.017
Enable
00.018 Preset Reference 1
00.025 User Security Code
Power-up Keypad
00.027
Control Mode
Reference
00.028 Ramp Mode Select
00.029 Ramp Enable
00.030 Parameter Cloning
00.031 Stop Mode
Dynamic V to F
00.032
Select / Flux
Optimization Select
Unidrive M200-201 Quick Start Guide
Issue Number: 6
Range
( )
OL
RFC-A
±VM_NEGATIVE_REF_CLAMP1 Hz
±VM_POSITIVE_REF_CLAMP Hz
±VM_ACCEL_RATE s/100 Hz
±VM_ACCEL_RATE s/100 Hz
AV (0), AI (1), AV.Pr (2), AI.Pr (3),
Preset (4), Pad (5), Pad.Ref (6),
E.Pot (7), torque (8), Pid (9)
0.00 to VM_RATED_CURRENT A
0.0 to 80000.0 rpm
0 to VM_AC_VOLTAGE_SET V
0.00 to 1.00
LEVEL.0 (0), ALL (1), r.only.0 (2),
r.only.A (3), Status (4), no.acc(5)
0.00 to 300.00 Hz
4-20.S (-6), 20-4.S (-5),
4-20.L (-4), 20-4.L (-3),
4-20.H (-2), 20-4.H (-1), 0-20 (0), 20-
0 (1), 4-20.tr (2), 20-4.tr (3),
4-20 (4), 20-4 (5), Volt (6)
Off (0) or On (1)
±VM_SPEED_FREQ_REF Hz
0 to 9999
Reset (0), Last (1), Preset (2)
Fast (0), Std (1), Std.bst (2),
Fst.bst (3)
Off (0) or On (1)
None (0), rEAd (1), Prog (2),
Auto (3), boot (4)
CoASt (0), rP (1), rP.dc I (2),
dc I (3), td.dc I (4), dis (5),
No.rP (6)
0 to 1
Default
( )
OL
RFC-A
0.00 Hz
50Hz default: 50.00 Hz
60Hz default: 60.00 Hz
5.0 s/100 Hz
10.0 s/100 Hz
AV (0)*
Maximum Heavy Duty
Rating A
50Hz default:
50Hz default:
1500.0 rpm
1450.0 rpm
60Hz default:
60Hz default:
1800.0 rpm
1750.0 rpm
110V drive: 230 V
200V drive: 230 V
400V drive 50 Hz: 400 V
400V drive 60 Hz: 460 V
0.85
LEVEL.0 (0)
1.50 Hz
Volt (6)
Off (0)
0.00 Hz
0
Reset (0)
Std (1)
On (1)
None (0)
rp (1)
0
Type
RW Num
US
RW Num
US
RW Num
US
RW Num
US
RW
Txt
PT US
RW Num
RA
US
RW Num
US
RW Num
RA
US
RW Num
RA
US
RW Num ND NC PT
RW Num
US
RW
Txt
US
RW
Bit
US
RW Num
US
RW Num ND NC PT US
RW
Txt
US
RW
Txt
US
RW
Bit
US
RW
Txt
NC
US
RW
Txt
US
RW Num
US
27