Bring-Up Of Managed Systems; Configuring Network Attributes; Figure 22: Two Power Inlets - Electric Caution Notifications - Mellanox Technologies SB7700 User Manual

1u edr 100gb/s infiniband switch systems
Hide thumbs Also See for SB7700:
Table of Contents

Advertisement

Rev 1.2
CAUTION
Risk of electric shock
and energy hazard. The
two power supply units
are independent.
Disconnect all power
supplies to ensure a pow-
ered down state inside of
the switch platform.
2.7

Bring-Up of Managed Systems

2.7.1

Configuring Network Attributes

The procedures described in this chapter assume that you have already installed and powered-on
the system according to the instructions in this document. Since the system comes with a pre-
configured DHCP, you may find the explanation in Section 2.7.1.1 sufficient. In case a manual
configuration is required, please refer to the instructions in Section 2.7.1.2.
2.7.1.1 Disable Dynamic Host Configuration Protocol (DHCP)
DHCP is used for automatic retrieval of management IP addresses..
28
Mellanox Technologies
After inserting a power cable and confirming the green System Status LED light is
on, make sure that the Fan Status LED shows green.
If the Fan Status LED is not green, unplug the power connection and check that the
fan module is inserted properly and that the mating connector of the fan unit is free of
any dirt and/or obstacles. If no obstacles were found and the problem persists, call
your Mellanox representative for assistance.

Figure 22: Two Power Inlets - Electric Caution Notifications

ACHTUNG
Gafahr des elektrischen
Schocks. Entferrnen des
Netzsteckers elnes Netz-
teils spannungsfrei. Um
alle Einhieten span-
nungsfrei zu machen
sind die Netzstecker
aller Netzteile zu ent-
fernen
If a user connects through SSH, runs the wizard and turns off DHCP, the connection is
immediately terminated as the management interface loses its IP address.
<localhost># ssh admin@<ip-address>
Mellanox MLNX-OS Switch Management
Password:
Mellanox Switch
Mellanox configuration wizard
Do you want to use the wizard for initial configuration? yes
Step 1: Hostname? [my-switch]
Step 2: Use DHCP on mgmt0 interface? [yes] no
<localhost>#
In such case the serial connection should be used.
ATTENTION
Risque de choc et de danger 
e'lectriques. Le de'branch-
ment d'une seule alimentation
stabilise'e ne de'branch
uniquement qu'un module
"Alimentation Stabilise'e".
Pour isoler completement le
module en cause, Il faut
de'brancher toutes les alimen-
tations stabilise'es.
電擊與能源危害的危險。
所有 PSU 均各自獨立。
將所有電源供應器斷電,確
保交換器平台內部在電源關
閉狀態。