S4 Terminal
S4 Terminal
Program
Input Terminals
This parameter selects the functionality of the S4 discrete input terminal.
In addition, the input terminal must be specified as Normally Open or
Normally Closed.
This parameter sets the programmable S4 terminal to 1 of the 69 possible
functions that are listed in
S5 Terminal
Program
Input Terminals
This parameter selects the functionality of the S5 discrete input terminal.
Note: The S5 input terminal may be used without the ASD-
Multicom option board.
Without the ASD-Multicom option board the S5 terminal
assignment information will be stored in volatile memory.
The terminal assignment information will be lost if the
system is powered down or reset.
In addition, the input terminal must be specified as Normally Open or
Normally Closed.
This parameter sets the programmable S5 terminal to 1 of the 69 possible
functions that are listed in
S5–S12 Terminal Delay
Program
Terminal Delays
This parameter delays the response of the ASD to any change in the S5–S12
terminal input by the programmed value (see waveforms at
The delay may be increased to provide additional electrical noise immunity or
to prevent the ASD from responding to contact bounce or chatter.
S6 Terminal
Program
Input Terminals
This parameter selects the functionality of the S6 discrete input terminal.
Note: The S6 input terminal may be used without the ASD-
Multicom option board.
Without the ASD-Multicom option board the S6 terminal
assignment information will be stored in volatile memory.
The terminal assignment information will be lost if the
system is powered down or reset.
In addition, the input terminal must be specified as Normally Open or
Normally Closed.
This parameter sets the programmable S6 terminal to 1 of the 69 possible
functions that are listed in
Q7 ASD Installation and Operation Manual
S4 Terminal
Table 7 on page
130.
S5 Terminal
Table 7 on page
130.
S5–S12 Delay
S6 Terminal
Table 7 on page
130.
Parameter Type — Selection List
Factory Default — Emergency Off
Changeable During Run — No
Parameter Type — Selection List
Factory Default — Unassigned
Changeable During Run — No
Parameter Type — Numerical
Factory Default — 8.0
FL Off
Delay).
Changeable During Run — No
Minimum — 2.0
Maximum — 200.0
Units — mS
Parameter Type — Selection List
Factory Default — Unassigned
Changeable During Run — No
S6 Terminal
113