OUT6 On Delay

OUT6 On Delay
Program
Terminal Delays
This parameter delays the response of the OUT6 output contacts by the
programmed value (see waveforms at
The delay may be increased to prevent relay chatter.

OUT6 Terminal

Program
Output Terminals
This parameter sets the functionality of the OUT6 output contacts to 1 of the 58
possible functions that are listed in
The on and off delay times of the OUT6 contacts may be adjusted to provide
more response time to the device that is connected to the output terminals.
In addition, the output contacts must be specified as Normally Open or
Normally Closed.
OUT7 Off Delay
Program
Terminal Delays
Once the condition is met to change the state of the OUT7 output contacts, this
parameter delays the response of the contacts by the programmed value (see
waveforms at
FL Off
Delay).
The on and off delay times of the OUT7 contacts may be adjusted to provide
more response time to the device that is connected to the output terminals.
OUT7 On Delay
Program
Terminal Delays
This parameter delays the response of the OUT7 output contacts by the
programmed value (see waveforms at
The delay may be increased to prevent relay chatter.

OUT7 Terminal

Program
Output Terminals
This parameter sets the functionality of the OUT7 output contacts to 1 of the 58
possible functions that are listed in
The on and off delay times of the OUT7 contacts may be adjusted to provide
more response time to the device that is connected to the output terminals.
In addition, the output contacts must be specified as Normally Open or
Normally Closed.
82
OUT6 On Delay
FL On
Delay).
OUT6 Terminal
Table 8 on page
133.
OUT7 Off Delay
OUT7 On Delay
FL On
Delay).
OUT7 Terminal
Table 8 on page
133.
OUT7 Terminal
Parameter Type — Numerical
Factory Default — 2.0
Changeable During Run — No
Minimum — 2.0
Maximum — 200.0
Units — mS
Parameter Type — Selection List
Factory Default — Reach Speed
Changeable During Run — No
Parameter Type — Numerical
Factory Default — 2.0
Changeable During Run — No
Minimum — 2.0
Maximum — 200.0
Units — mS
Parameter Type — Numerical
Factory Default — 2.0
Changeable During Run — No
Minimum — 2.0
Maximum — 200.0
Units — mS
Parameter Type — Selection List
Factory Default — OC Alarm
Changeable During Run — No
Q7 ASD Installation and Operation Manual