NOTE: The checkmarks highlight which options are selected.
ARM
Digit
FAULTED
0
1
2
3
4
5
6
7
ARM FAULTED - If enabled, this allows the user to arm the system independent of the status of any
delay or interior zones. If the system is armed with any delay or interior zone faulted, an Exit Error
occurs at the end of the exit time unless the faulted zones become restored.
DIALING PULSE TYPE - Specifies how this control will perform pulse dialing (U.S. Pulse or
European Pulse) when CS transmissions are enabled.
AUTO STAY - If enabled, the system will arm Auto Stay, bypassing interior zones programmed as
Stay zones if the Entry Exit zone is not faulted during exit time. If an instant zone or a delay zone is
programmed for Bypass in Stay, the panel will not arm Auto Stay if it is enabled.
Question 07 L3
Quick Commands & Quick Exit
Enter the digit from the table below in Location L2.
NOTE: The checkmarks highlight which options are selected.
QUICK FORCED
Digit
ARMING
0
NONE
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
DIALING PULSE TYPE
US
EUROPEAN
QUICK COMMANDS
QUICK
ARMING
Section 7 - System Programming
AUTO
STAY
U L
European Pulse has not been tested for
UL installations.
QUICK
QUICK
BYPASS
EXIT
Default = 0
U L
For UL installations, do not
select Quick Forced Arming.
7–7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omni 408eu

Table of Contents