Honeywell OMNI 408 Installation And Setup Manual page 50

Fbii hardwired/wireless system
Table of Contents

Advertisement

OMNI-408/OMNI-408EU Installation and Setup Guide
INTERIOR - All interior zones have exit delay time upon system arming. Furthermore, all interior
zones have entry delay time if a delay zone is violated first. If this zone is violated first, however, it
generates an immediate alarm. Interior zones are bypassed and the Interior zone is programmed for
Stay if the system is armed in the Stay mode. Interior zones employ the Exit Error Warning feature
described in the note below.
PERIMETER - This zone type (sometimes known as Instant) generates an alarm when violated while
the system is armed.
Burglary Zone Options
RESTORE - This option is selected for all burglary zones by enabling the Restore report code
(Question 19, Location 2) and enabling zone Restores in Question 06, Location 4. The programmed
Restore code will be reported upon bell cutoff, assuming the loop is restored, unless Restore Follows
Loop is selected in Question 07, Location 4. The Restore code will also be reported if the system is
disarmed during an alarm.
NOTE: Restore is not selectable by zone.
BYPASS IN STAY - This option allows zones to be bypassed when the system is armed in the Stay
mode and if the zone is programmed as a Stay zone (Location 4 of each zone).
CHIME - If this option is selected, the keypad sounder will annunciate for 1 second when this zone is
violated in the disarmed mode.
DIALER DELAY - If this option is selected, the system will allow a 15-second delay (or 30 seconds, as
per Question 06, Location 4) before dialing, allowing the end user to abort the transmission. If this
option is not selected, any alarm condition results in an immediate
U L
For UL installations, Dialer Delay may not be used.
DAY FEATURE - If a zone with this option is violated while the system is disarmed, the keypad
sounder and zone LED pulse for as long as the violation remains. In addition, if the violation remains
for 15 seconds, the System Trouble Code is transmitted to the central station. The sounder can be
silenced through entry of any valid user code. While the system is armed, a day zone acts as an alarm
when violated.
Zones 1-8 can be programmed for any one of the following 24-hour zone types:
7–18

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omni 408eu