OMNI-408/OMNI-408EU Installation and Setup Guide
Digit
0
1
2
3
4
5
6
7
Question 08 L3
Burglary Bell Cutoff
Enter the desired bell cutoff time on alarm conditions for burglary and panic in 3-minute intervals (for
example, 3 = 9 minutes). The valid range of input is 1 - F, with F indicating an infinite burglary bell
cutoff time.
Digit
1
2
3
4
5
6
7
8
U L
Must be programmed as "2" for UL installations.
Question 08, L4
Fire Bell Cutoff
Using the table in Question 08, Location 3 to determine valid choices, enter the desired bell cutoff time
for fire conditions in 3-minute intervals (for example, 3 = 9 minutes). The valid range of input is 1 - F,
with F indicating an infinite fire bell cutoff time.
U L
Must be programmed as "2" for UL installations.
7–10
EXIT TIMEOUTS
1 second
10 seconds
20 seconds
30 seconds
40 seconds
50 seconds
1 minute
1 minute 10 seconds
BURGLARY & FIRE
BELL TIMEOUTS
3 minutes
6 minutes
9 minutes
12 minutes
15 minutes
18 minutes
21 minutes
24 minutes
Digit
EXIT TIMEOUTS
8
1 minute 20 seconds
9
1 minute 30 seconds
A
1 minute 40 seconds
B
1 minute 50 seconds
C
2 minutes
D
2 minutes 10 seconds
E
2 minutes 20 seconds
F
3 minutes
BURGLARY & FIRE
Digit
BELL TIMEOUTS
9
27 minutes
A
30 minutes
B
33 minutes
C
36 minutes
D
39 minutes
E
42 minutes
F
Infinite
Default = 5
Default = F