Jam Type: The jam type defines the criteria that the jam signal must meet to be considered a valid
jamming signal. The types are as follows:
EUROPEAN (Euro): If a jam signal is detected for a total of 30 seconds in a 60-second period (not
necessarily in one continuous stretch), then qualify it as a jam condition and report it.
DOMESTIC (US): If a jam signal is detected for a period of 20 consecutive seconds, then qualify it
as a jam condition and report it.
Jam Detection Action: The actions that can be taken by the system when a valid jam signal is
detected is to remain silent, sound the keypad sounder or alarm sounder, or sound both the keypad
sounder and alarm sounder.
Question 28, L3 & L4 – Jamming Reporting Code to CS
The same rules for programming regarding dialer format apply here. If transmissions are not desired,
program AA in locations L3 and L4.
QUESTION 29
CID GROUP NUMBER
Question 29, L1 & L2 - Account 1 Group Number
Question 29, L1 & L2 - Account 2 Group Number
This question contains the group number that is to be sent in Contact ID format. L1 and L2 contain the
group number that is sent when account number 1 is used. L3 and L4 contain the group number that is
sent when account number 2 is used.
QUESTION 30
CS CODES: EXIT PROGRAM, EXIT ERROR, RECENT PANIC
Question 30, L1 -L2 Exit Programming CS Code
Question 30, L3 - Exit Error CS Code
Question 30, L4 - Recent Panic CS Code
U L
Recent Panic has not been evaluated by UL and must not be used for UL installations.
EXIT PROGRAM CS REPORTING - The Exit Program CS Reporting feature is enabled by placing
an event code in Question 30, Locations 1 and 2. Letters "AA" in Location 1 disable the feature. Once
enabled, this code is sent ONLY upon exiting keypad programming by pressing the [STAY] [1] [3]
(default), or [7] [9] (user default) keys. The feature is NOT affected by the following: remote
upload/download, power down/up, hardwire default, system reset, and entering or exiting other
installer modes such as walk test, unattended, and online download.
EXIT ERROR CS REPORTING - The Exit Error CS Reporting feature is enabled in Question 30,
Location 3. A letter "A" disables the CS report. During an exit error, this code is sent after the control
panel's entry time expires and the zone goes into alarm. If the system is disarmed before entry time
Section 7 - System Programming
Default = AA
DEFAULT = AAAA
Default = AA
Default = AA
DEFAULT = AAAA
Default = AA
Default = A
Default = A
7–29