IP Phone diagnostic utilities
Figure 110: Ethernet Statistics
Using Ethernet Statistics tool
1. Press the Services key twice.
2. Press the left or right navigation keys to access the Diagnostics menu.
3. Press 3 on the dialpad to access the Ethernet Statistics menu or use the Up or
4. Press the Select soft key.
608
IP Deskphones Fundamentals
Down navigation keys to scroll and highlight the Ethernet Statistics option.
You can press the Cancel soft key exit the menu to return to the Diagnostics
menu.
The screen displays Reset, NIport/PCPort, and Cancel soft keys. The NIport soft
key is used to select the Network (NI) Port or the PC (PC) Port. The soft key label
indicates the current display page. For example, when NIport appears on the soft
key label, the information showing on the display is for the network interface port.
When NIport appears on the second soft key label, the following statistics are
displayed
• Link Status
• Duplex Mode
• Network Speed (10 Mb, 100 Mb, or 1 G)
• AutoSense/Negotiate
- AutoSense/Negotiate Capability
- AutoSense/Negotiate Completed
• Port VLAN Priority
• Port VLAN ID
• Packet Collision
• CRC Error count
• Frame Error count