Output Assemblies (Drive Consumes) - YASKAWA v1000 Installation Manual

Ethernet/ip
Hide thumbs Also See for v1000:
Table of Contents

Advertisement

8

Output Assemblies (Drive Consumes)

Note:
The convention in this manual is from the PLC perspective. As such, an assembly is called an "Output
Assembly" when outputted from the PLC and received by this node. This section details "Output
Assemblies" that are "Consumed" by this drive.
u
Basic Speed Control Output - 20 (0x14)
Output
Word
Instance
0
20
1
Name
Forward Run Command
Run Fwd
0: Stop
1: Forward Run
Fault Reset
Fault Reset
(0 to 1 transition: Fault Reset)
Speed Command
Sets drive speed reference.
Speed reference data: Frequency reference/2
Speed Reference
Setting range: 0 to 0xFFFF
Example: setting a reference of 4096 with a speed scale of 2:
Speed reference data = 4096/2
Unit depends on o1-03.
YASKAWA TOEP YAICOM 15A V1000 Option Dual-Port EtherNet/IP SI-EN3D/V Installation Manual
Byte
Bit 7
Bit 6
0
1
2
3
2
= 1024 = 0x0400 Hex or 10.24 Hz
8 Output Assemblies (Drive Consumes)
Bit 5
Bit 4
Bit 3
Speed Reference (Low Byte)
Speed Reference (High Byte)
Description
SS
(SS: Speed scale)
Bit 2
Bit 1
Fault
Reset
Bit 0
Run
Fwd
35