(2) Side 1 alignment
(a) Key in
"El".
(CALIBRATION SIDE 1 ALIGNMENT)
(b) The same as in item (l)-(b)
(d)
.
(3) Index burst timing
i a !
Q-.-
i n
"E5".
(CALIBRATION INDEX TIMING)
(b) Calibration value set at that time is indicated in the latter three
digits of the DATA indicator, XXXX (us), and the polarity is indicated
in the initial digit.
Refer to item (l)-(b).
If a
"0"
is indicated, the polarity is positive.
(c) Key in a polarity and a new calibration value (three digits,
Max.)
of
side 0 written on the alignment disk label. Refer to item (l)-(c) as
to the polarity designation.
Notes: 1 . If the side is changed by key "4" for a double sided FDD, new
calibration value for side 1 shall be keyed in.
Refer to item
3-2-4-4,
Note 1.
2 .
If there is no change in the calibration value in item (b)
,
omit item
(c).
(d) Depress "F" key.
(STOP)
e.g. Double sided FDD, SIDE
0
ALIGNMENT +3%, SIDE 1 ALIGNMENT -5%,
INDEX TIMING - 2 5 ~ ~ :
EO
3 F,
E l
B5
F, E5
B25 F
-
3224
-