Storage Controller Troubleshooting - IBM totalstorage 326 User Reference

Network attached storage 300
Hide thumbs Also See for totalstorage 326:
Table of Contents

Advertisement

114
Model 326 User's Reference
Table 21. Storage controller troubleshooting
Problem indicator
Component
Amber LED on
Drive CRU
Fan CRU
RAID controller
Fault LED
Expansion port
bypass LED
Front panel
Amber LED is on and
Power-supply
green LED off
CRU
Amber and green LEDs
Power-supply
on
CRU
All green LEDs off
All CRUs
Amber LED flashing
Drive CRUs
Possible cause
Possible solutions
Drive has failed
Replace the drive that
has failed.
Fan failure
Replace the fan that has
failed.
RAID controller has
If the RAID controller
failed
Fault LED is on, replace
the RAID controller.
GBIC port empty
No corrective action is
needed if the system is
properly configured.
Fibre Channel cable
No corrective action is
is not attached to
needed.
the expansion unit
No incoming signal
1. Reattach the GBIC
detected
2. Replace input and
General system
Indicates that a Fault
error
LED somewhere on the
storage controller has
turned on. (Check for
amber LEDs on CRUs.)
Power switch is
Turn on all power-supply
turned off or AC
power switches.
power failure
Power supply failure Replace the failed
power-supply CRU.
Subsystem power is
Check that all
off
storage-controller power
cords are plugged in and
the power switches are
on. If applicable, check
that the main circuit
breakers for the rack are
turned on.
AC power failure
Check the main circuit
breaker and AC outlet.
Power supply failure Replace the power
supply.
Midplane failure
Have the storage
controller serviced.
Drive rebuild or
No corrective action is
identity is in process
needed.
and Fibre Channel
cables.
output GBIC or
cables as necessary.