Testing The Fibre Channel Host Adapter With Fastt Msj; Scsi Hvd 3570 Adapter Troubleshooting Chart - IBM totalstorage 326 User Reference

Network attached storage 300
Hide thumbs Also See for totalstorage 326:
Table of Contents

Advertisement

Table 17. SCSI HVD 3570 adapter troubleshooting chart
SCSI HVD 3570 adapter
problem
The adapter is not operating
correctly.
Adapter stops operating
correctly without apparent
cause.
BIOS startup messages

Testing the Fibre Channel host adapter with FAStT MSJ

Note: Ensure that there is no adapter activity before running the test to avoid
The Model 326 engine comes with FAStT MSJ for viewing the status of the Fibre
Channel connection as well as testing the adapter or cable. To use FAStT MSJ, first
start Terminal Services. For instructions on how to invoke Terminal Services, see
"Terminal Services and the IBM NAS Administration Console" on page 12.
You access FAStT MSJ by starting the IBM NAS Admin console, selecting NAS
Management → Storage → NAS Utilities → FAStT MSJ. Then, select Connect. A
diagnostic panel displays the following general information related to the Fibre
Channel adapter which can be useful if you need to place a support call:
v Node name
v Serial number (in hex)
v Loop ID
v BIOS version
v Firmware version number
v Device driver version number
v PCI slot number
FAStT MSJ also provides the Model 326 engine's world-wide name (WWN) as
detailed in "Managing Fibre Channel host bus adapters" on page 77.
108
Model 326 User's Reference
Suggested action
1. Ensure the adapter is seated correctly.
2. Ensure that all of the SCSI devices are on.
3. Ensure that all bus and power cables are connected correctly.
4. Ensure that the host adapter and all SCSI devices have unique SCSI IDs.
5. Ensure that the pin-1 orientation is maintained throughout the bus.
6. Replace the adapter.
1. Run the diagnostics.
2. Reseat the adapter in its slot, or use a different slot, if necessary.
3. The network driver files might be corrupt or missing. Remove and then reinstall
the drivers.
Device connected, but not ready
Set the Send Start Unit Command to Yes for the host adapter.
Start unit request failed
Set the Send Start Unit Command to No for the device.
Time-out failure during...
Ensure the SCSI bus is terminated correctly by following these steps:
1. Disconnect the peripheral cables from the host adapter.
2. Restart the engine.
3. If the engine restarts successfully, check the bus terminations and cable
connections. Also, one of the devices on the bus might be defective.
losing data.

Advertisement

Table of Contents
loading

Table of Contents