IBM totalstorage 326 User Reference page 180

Network attached storage 300
Hide thumbs Also See for totalstorage 326:
Table of Contents

Advertisement

168
Model 326 User's Reference
Table 31. Hub diagnostic error messages (continued)
Message
DIAG-MEMORY Err#0110
[ramTest]
DIAG-PORTABSENT
Err#2670, 3070, 3870
[portLoopbackTest,
crossPortTest, spinSilk]
DIAG-PORTDIED Err#265F,
305F, 385F
[portLoopbackTest,
crossPortTest, spinSilk]
DIAG-PORTSTOPPED
Err#3874 [spinSilk]
DIAG-PORTWRONG
Err#3078 [crossPortTest]
DIAG-POST_SKIPPED Err#
0004 [managed hub
initialization]
DIAG-REGERR Err#0B15,
0415 [portRegTest,
sramRetentionTest]
DIAG-REGERR_UNRST
Err#0B16, 0416 [portRegTest,
sramRetentionTest]
DIAG-STATS Err#2660 - 2662,
3060 - 3062 [portLoopback
Test, crossPortTest]
DIAG-TIMEOUT Err#266F,
306F, 386F
[portLoopbackTest,
crossPortTest,
centralMemoryTest]
DIAG-XMIT Err#2271, 2671,
3071, 3871
[portLoopbackTest,
crossPortTest, spinSilk,
camTest]
Description
Data read from RAM
location did not match
previously written data into
same location.
Port is not present.
Port was in loopback mode
and then went inactive.
Port is no longer
transmitting, as indicated by
the number of frames
transmitted counter being
stuck at N frames.
Frame erroneously received
by port M instead of the
intended port N.
POST is skipped. Its
message recommended
that POST be executed.
Data read from ASIC
register or ASIC SRAM did
not match data previously
written into same location.
Port failed to unreset.
Port counter value did not
match the number of
frames actually transmitted.
Possible counters reporting:
v FramesTx - number of
frames transmitted
v FramesRx - number of
frames received
v Cl3FrmRx - number of
class 3 frames received
v For portLoopbackTest
and crossPortTest: port
failed to receive frame
within time-out period.
v For centralMemoryTest:
port failed to detect an
interrupt within the
timeout period.
Port failed to transmit
frame.
Probable cause
Action
CPU RAM failure
1
ASIC or system
1
board failure
ASIC, GBIC
2
module, embedded
optic or fiber cable
failure
ASIC, GBIC
2
module, embedded
optic or fiber cable
failure
ASIC failure
1
Informational only
None
required
ASIC failure
1
ASIC failure
1
ASIC, GBIC
2
module, embedded
optic or fiber cable
failure
ASIC, GBIC
2
module, embedded
optic or fiber cable
failure
ASIC failure
1

Advertisement

Table of Contents
loading

Table of Contents