With this method, you can use the Storage Manager client software to manage the
storage subsystem directly over the network through each controller's Ethernet
connection. To manage a controller directly, you need:
v A Windows 2000 client computer connected to the local Ethernet network.
v Storage Manager client software. The Storage Manager client software package
v DHCP server connected to the local Ethernet network.
v One Ethernet cable for each storage-subsystem controller in the 5191 RAID
v Ethernet hub or switch.
To install and configure using the direct-managed method:
1. Install the SM client software on the Windows 2000 client computer (not Node A
2. Connect each storage-subsystem controller in the 5191 RAID Storage Controller
3. Start Storage Manager. The Enterprise Management window appears and a
If the subsystems do not appear, then the IP address assigned to each
storage-subsystem controller in the 5191 RAID Storage Controller must be identified
so it can be input into the Storage Manager Application. To identify the IP
addresses:
1. Record the Ethernet MAC addresses of each storage-subsystem controller in
2. On the DHCP server, locate the IP addresses (either two or four) that were
3. From the Storage Manager Enterprise Management window, select Edit → Add
The storage can now be managed using the external Ethernet connection
regardless of the state of the Node A and Node B engines.
30
Model 326 User's Reference
can be downloaded from the NAS 5195 Model 326 download Web page using
the following URL:
http://ssddom02.storage.ibm.com/techsup/nas/nasdown.nsf/fToolProdView/KUGPJE9903P?
Openform
Storage Controller to connect to the local Ethernet network. (One dual storage
subsystem controller 5191 RAID Storage Controller is equivalent to two Ethernet
cables; two dual storage-subsystem controller 5191 RAID Storage Controller
Units are equivalent to four Ethernet cables.)
or Node B).
to an existing Ethernet network using Ethernet cables. A separate stand-alone
diagnostic network can be created by connecting the SM client computer, DHCP
computer and all storage subsystem controllers to an Ethernet hub.
pop-up window indicates that it is not configured to monitor any devices. Select
Yes to have it search for subsystems.
the 5191 RAID Storage Controller Unit. The MAC address is located on a label
directly under the RJ-45 Ethernet port on the rear of each storage-subsystem
controller; for example, a MAC address could appear as 10-11-12-13-14-15.
assigned to the MAC addresses of the storage-subsystem controllers.
Device and add the IP addresses that were assigned to the storage-subsystem
controllers.