IBM totalstorage 326 User Reference page 163

Network attached storage 300
Hide thumbs Also See for totalstorage 326:
Table of Contents

Advertisement

Table 28. Diagnostic error messages (continued)
Error Code
Meaning
166-342-000
System Management failed:
Remote Supervisor Adapter
BIST indicate failed tests).
166-400-000
System Management failed:
System management
hardware on system board
failed) (ISMP Self Test Result
failed tests: x where x =
Flash, RAM, or ROM).
180-XXX-000
Diagnostics LED failure
180-XXX-001
Failed front LED panel test
180-XXX-002
Failed diagnostics LED panel
test
180-XXX-005
Failed SCSI backplane LED
test
180-XXX-006
Memory Board LED test
180-361-003
Failed fan LED test
201-XXX-0NN
Failed Memory test
201-XXX-999
Multiple DIMM failure; see
error text for failing DIMMs
202-XXX-001
Failed system cache test
202-XXX-002
Failed system cache test
206-XXX-000
Failed diskette drive test
215-XXX-000
Failed IDE CD-ROM test
217-198-XXX
Could not establish drive
parameter
FRU/action
1. Ensure that the latest firmware levels for the Remote
Supervisor Adapter and BIOS
2. Disconnect all server and option power cords from the
unit, wait 30 seconds, reconnect, then retry.
3. Remote Supervisor Adapter
1. Re-flash or update firmware for ISMP
2. System board
Run the diagnostics LED test for the failing LED.
1. System board
2. Power-switch assembly
1. SCSI backplane
2. SCSI backplane cable
3. System board
Suspected part:
1. Memory
2. Processor/PCI board
3. System board
1. Fans
2. System board
1. DIMM Location DIMM1 - DIMM4 where NN can be a
value from 01 to 04. 01 = DIMM2, 02 = DIMM1, 03 =
DIMM4, 04 = DIMM3
2. System board
1. See error text for failing DIMMs
2. System board
1. VRM 1
2. Microprocessor 1
1. VRM 2
2. Microprocessor 2
1. Cable
2. Diskette drive
3. System board
1. CD-ROM drive cables
2. CD-ROM drive
3. System board
1. Check cable and termination
2. SCSI backplane
3. Fixed disk
Appendix D. Engine POST and diagnostic program messages
151

Advertisement

Table of Contents
loading