IBM totalstorage 326 User Reference page 155

Network attached storage 300
Hide thumbs Also See for totalstorage 326:
Table of Contents

Advertisement

Table 27. POST error messages (continued)
Error
Meaning
code/Symptom
1600
The Service Processor is not
functioning
1601
The system is able to
communicate to the Service
Processor, but the Service
Processor failed to respond
at the start of POST
1762
Hard-disk-drive configuration
error
178X
Hard-disk-drive error
1800
No more hardware interrupts
available for PCI adapter
1962
Drive does not contain a
valid boot sector
5962
IDE CD-ROM configuration
error
8603
Pointing-device error
FRU/action
1. Ensure that a jumper is not installed on J-51
2. Remove the AC power to the system, wait 20 seconds
and then reconnect the AC power. Wait 30 seconds; then,
power-on the appliance.
3. System board
4. Processor/PCI board
Suspected part:
1. Remove the AC power to the system, wait 20 seconds,
and reconnect the AC power. Wait 30 seconds and
power on the system.
2. Flash update the service processor.
3. System board
4. Processor/PCI board
1. Run Configuration/Setup
2. Hard disk cables
3. Hard disk adapter
4. Hard disk drive
5. SCSI backplane
6. System board
1. Run diagnostics
2. Hard disk cables
3. Hard disk adapter
4. Hard disk drive
5. System board
1. Run Configuration/Setup
2. Failing adapter
3. System board
1. Verify that a bootable operating system is installed.
2. Run diagnostics
3. Hard disk drive
4. SCSI backplane
5. Cable
6. System board
1. Run Configuration/Setup
2. CD-ROM drive
3. CD-ROM power cable
4. IDE Cable
5. System board
6. Battery
1. Pointing device
2. System board
Appendix D. Engine POST and diagnostic program messages
143

Advertisement

Table of Contents
loading

Table of Contents