10.0 Upgrading Firmware Procedure
Some Versions of S200 OC TOOLS mistakenly refer to switch S13 as S3.
NOTE
d. A progress window will come up to indicate the firmware load is taking place. Upon completion S200
OC TOOLS will put up a status box asking you to turn S13 back to it's original (UP) position and cycle
power on the drive BEFORE clicking the 'OK' box. S200 OC TOOLS will then begin to operate normally
with a data refresh.
8.) Use S200 OC Tools to return RS232.Baudrate, if required, to its setting as recorded in step 4.
9.) Return the Modbus Address switches to the setting recorded in step 1, if required.
10.) Cycle Drive Power
11.) Use the Communication Wizard to adjust Modbus Address and Baud rate accordingly.