7.2.2 Communication Wizard

A communications wizard can be found under the Utilities menu. This allows you to select the
RS232 communications port for the computer, Modbus address of the unit to communicate to
(S11 And S12), and the baud rate (Default to 38400). A simple test of communications. Other port
parameters are automatically set by S200 OC TOOLS.

7.2.3 Mouse Flags

Hovering the mouse pointer over data locations on the GUI will cause the name of the associated
variable to show. The Variable browser or On-Line Variable editor can then be used with
knowledge of the association.