Danaher Motion s200 User Manual page 68

Position node
Table of Contents

Advertisement

9.0 Serial Communications and Modbus RTU
PDID
Modbus
Name
Index
Address
511
1022
IN8MODE
513
1026
IN9
514
1028
IN9MODE
549
1098
O3
550
1100
O3MODE
551
1102
O3TRIG
1008
2016
Motor.Name
1009
2018
KVP
1010
2020
KVI
1011
2022
ILmtPlus
1012
2024
ILmtMinus
1013
2026
BU.Error.code
1014
2028
OC.Error.code
1015
2030
Warning.Code
1017
2034
DPoles
1025
2050
KPP
1026
2052
KVFF
1027
2054
KTFF
1028
2056
AVGTIME
1200
2400
Save
1201
2402
Fault Reset
1202
2404
SW Enable
1203
2406
En Stat
1204
2408
Coldstart
1210
2420
MT.Number
64
07/06
Data
Rights Default
Min Value Max
Type
Value
Long
R/W
9
Long
RO
0
Long
R/W
9
Long
R/W
0
Long
R/W
0
Long
R/W
0
-2.15E+09 2.147E+09
String
R/W
Float
R/W
0.014
Long
R/W
100
Long
R/W
50
Long
R/W
50
Long
RO
0
Long
RO
0
Long
RO
0
Long
R/W
10
Float
R/W
16
Long
R/W
100
Long
R/W
1
Long
R/W
0
Long
WO
0
Long
WO
0
Long
R/W
AENA
Long
RO
AENA
Long
WO
0
Long
R/W
0
Danaher Motion
Units
Comments
Value
0
90 List
Sets function of DINP9
0
1 On/Off
Returns the state of DINP10
0
90 List
Sets function of DINP10
0
1 On/Off
Returns the state of DOUT3 or if O3MODE=0
can turn on or off DOUT3
0
100 List
Sets the function of DOUT3
Sets trigger level associated with O3MODE
ASCII
Motor Name String
0.001
110.769 A/(rad/s)
Velocity Loop Proportional gain
0
3000 Hz
Velocity Loop Integrator Rate
0
100 %
Positive Current Limit
0
100 %
Negative Current Limit
0 4.295E+09 List
Base Unit Error Code
0 4.295E+09 List
Position Node fault code
0 4.295E+09 List
Position Node Warning Code
2
254 Pole-pairs
Motor's pole pair
0
300 (rad/s)/rad
Position Loop Proportional gain
0
1000 %
Position Loop Velocity Feed forward tuning
parameter
0
1000 %
Position Loop Acceleration Feed Forward tuning
parameter
0 4.295E+09 Reads
Sets the number of reads used to average data
over for presentation to the user.
0
1 Command
Writing a 1 to this location causes the S200
Position Node to save parameters to non-
volatile memory.
0
1 Command
Writing a 1 to this location causes the S200
Position Node to attempt a fault reset.
0
1 Command
Writing a 0 disables the drive, writing a 1
enables the drive. Default depends on AENA.
0
16 Bit Code
Enable Status: Bit 0 = Fault, Bit 1 = Reserved,
Bit 2 = Coldstart Required, Bit 3: Reserved.
0
1 Command
Writing a one to this register starts the Coldstart
Process.
0
180 Number
Writing 0-180 to this register causes the S200
Position Node to populate the values of
PDID1215 through 1224 with the data for the
motion task whose number was written to this
S200 Position Node User's Guide

Advertisement

Table of Contents
loading

Table of Contents