Selecting a non-SFD motor automatically sets a related setting: Use SFD
Parameters (Under Drive Setup Menu) to 'Do Not Use SFD Parameters'.
Should the user go back to using an SFD supported motor the 'Use SFD
Parameters' setting is not automatically changed and should be changed
by the user.
NOTE
When the SFD parameters are not to be used the user must select the motor under the Motor
Setup menu. If the motor is not present in the motor data base the user must enter it into the
database. The Utilities Menu \ Motor Database editor is used. Run the database editor, Select
'New Motor', fill out the data sheet, press 'Add' and exit. The new motor will appear as a choice in
the Motor Selection Combo box.
To be clear, the above table represents the data stored in an SFD device. If 'Do Not Use SFD
Parameters' is selected in the Drive Setup screen the customer's entered data will be used. If
'Use SFD Parameters' is selected this data will be over-written with the data in the SFD.
27