GE T60 Instruction Manual page 635

Transformer protection system ur series
Hide thumbs Also See for T60:
Table of Contents

Advertisement

APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 55 of 74)
ADDR
REGISTER NAME
IEC 61850 Received Analogs (Read Only) (32 Modules)
B210
IEC 61850 Received Analog 1
B212
...Repeated for Received Analog 2
B214
...Repeated for Received Analog 3
B216
...Repeated for Received Analog 4
B218
...Repeated for Received Analog 5
B21A
...Repeated for Received Analog 6
B21C
...Repeated for Received Analog 7
B21E
...Repeated for Received Analog 8
B220
...Repeated for Received Analog 9
B222
...Repeated for Received Analog 10
B224
...Repeated for Received Analog 11
B226
...Repeated for Received Analog 12
B228
...Repeated for Received Analog 13
B22A
...Repeated for Received Analog 14
B22C
...Repeated for Received Analog 15
B22E
...Repeated for Received Analog 16
B230
...Repeated for Received Analog 17
B232
...Repeated for Received Analog 18
B234
...Repeated for Received Analog 19
B236
...Repeated for Received Analog 20
B238
...Repeated for Received Analog 21
B23A
...Repeated for Received Analog 22
B23C
...Repeated for Received Analog 23
B23E
...Repeated for Received Analog 24
B240
...Repeated for Received Analog 25
B242
...Repeated for Received Analog 26
B244
...Repeated for Received Analog 27
B246
...Repeated for Received Analog 28
B248
...Repeated for Received Analog 29
B24A
...Repeated for Received Analog 30
B24C
...Repeated for Received Analog 31
B24E
...Repeated for Received Analog 32
IEC 61850 Configurable Report Settings (Read/Write Setting)
B290
IEC 61850 configurable reports dataset items (64 items)
IEC 61850 XSWI Configuration (Read/Write Setting) (24 Modules)
B370
Flexlogic Operand for IEC 61850 XSWI.ST.Loc Status
IEC 61850 XSWI Configuration (Read/Write Command) (24 Modules)
B372
Command to Clear XSWI OpCnt (Operation Counter)
B373
...Repeated for module number 2
B376
...Repeated for module number 3
B379
...Repeated for module number 4
B37C
...Repeated for module number 5
B37F
...Repeated for module number 6
B382
...Repeated for module number 7
B385
...Repeated for module number 8
B388
...Repeated for module number 9
B38B
...Repeated for module number 10
B38E
...Repeated for module number 11
B391
...Repeated for module number 12
B394
...Repeated for module number 13
B397
...Repeated for module number 14
B39A
...Repeated for module number 15
GE Multilin
RANGE
-1000000000000 to
1000000000000
0 to 848
0 to 4294967295
0 to 1
T60 Transformer Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
0.001
F060
---
1
F615
---
1
F300
---
1
F126
DEFAULT
0
B
0 (None)
0
0 (No)
B-63

Advertisement

Table of Contents
loading

Table of Contents