B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 38 of 74)
ADDR
REGISTER NAME
7149
Ground Distance Zone 1 Reverse Reach
717A
Ground Distance Zone 1 Reverse Reach RCA
714B
Reserved (7 items)
7152
...Repeated for Ground Distance Zone 2
7174
...Repeated for Ground Distance Zone 3
B
7196
...Repeated for Ground Distance Zone 4
71B8
...Repeated for Ground Distance Zone 5
Phase Directional Overcurrent (Read/Write Grouped Setting) (2 Modules)
7200
Phase Directional Overcurrent 1 Function
7201
Phase Directional Overcurrent 1 Source
7202
Phase Directional Overcurrent 1 Block
7204
Phase Directional Overcurrent 1 ECA
7205
Phase Directional Overcurrent 1 Pol V Threshold
7206
Phase Directional Overcurrent 1 Block Overcurrent
7207
Phase Directional Overcurrent 1 Target
7208
Phase Directional Overcurrent 1 Events
7209
Reserved (8 items)
7211
...Repeated for Phase Directional Overcurrent 2
Neutral Directional Overcurrent (Read/Write Grouped Setting) (2 Modules)
7230
Neutral Directional Overcurrent 1 Function
7231
Neutral Directional Overcurrent 1 Source
7232
Neutral Directional Overcurrent 1 Polarizing
7233
Neutral Directional Overcurrent 1 Forward ECA
7234
Neutral Directional Overcurrent 1 Forward Limit Angle
7235
Neutral Directional Overcurrent 1 Forward Pickup
7236
Neutral Directional Overcurrent 1 Reverse Limit Angle
7237
Neutral Directional Overcurrent 1 Reverse Pickup
7238
Neutral Directional Overcurrent 1 Target
7239
Neutral Directional Overcurrent 1 Block
723B
Neutral Directional Overcurrent 1 Events
723C
Neutral Directional Overcurrent 1 Polarizing Voltage
723D
Neutral Directional Overcurrent 1 Op Current
723E
Neutral Directional Overcurrent 1 Offset
723F
Neutral Directional Overcurrent 1 Pos Seq Restraint
7240
Reserved
7241
...Repeated for Neutral Directional Overcurrent 2
Breaker Arcing Current Settings (Read/Write Setting) (6 Modules)
7290
Breaker 1 Arcing Amp Function
7291
Breaker 1 Arcing Amp Source
7292
Breaker 1 Arcing Amp Init
7294
Breaker 1 Arcing Amp Init B
7296
Breaker 1 Arcing Amp Init C
7298
Breaker 1 Arcing Amp Delay
7299
Breaker 1 Arcing Amp Limit
729A
Breaker 1 Arcing Amp Block
729C
Breaker 1 Arcing Amp Target
729D
Breaker 1 Arcing Amp Events
729E
...Repeated for Breaker 2 Arcing Amp
72AC
...Repeated for Breaker 3 Arcing Amp
72BA
...Repeated for Breaker 4 Arcing Amp
72C8
...Repeated for Breaker 5 Arcing Amp
72D6
...Repeated for Breaker 6 Arcing Amp
Disconnect (Breaker) Switch (Read/Write setting) (24 Modules)
B-46
RANGE
0.02 to 500
30 to 90
0 to 65535
0 to 1
0 to 5
0 to 4294967295
0 to 359
0 to 3
0 to 1
0 to 2
0 to 1
0 to 1
0 to 1
0 to 5
0 to 4
-90 to 90
40 to 90
0.006 to 30
40 to 90
0.002 to 30
0 to 2
0 to 65535
0 to 1
0 to 1
0 to 1
0 to 250
0 to 0.5
0 to 1
0 to 1
0 to 5
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 50000
0 to 4294967295
0 to 2
0 to 1
T60 Transformer Protection System
APPENDIX B
UNITS
STEP
FORMAT
ohms
0.01
F001
degrees
1
F001
---
1
F001
---
1
F102
---
1
F167
---
1
F300
---
1
F001
pu
0.001
F001
---
1
F126
---
1
F109
---
1
F102
---
1
F001
---
1
F102
---
1
F167
---
1
F230
° Lag
1
F002
degrees
1
F001
pu
0.001
F001
degrees
1
F001
pu
0.001
F001
---
1
F109
---
1
F300
---
1
F102
---
1
F231
0 (Calculated V0)
---
1
F196
0 (Calculated 3I0)
ohms
0.01
F001
---
0.001
F001
---
1
F001
---
1
F102
---
1
F167
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
kA2-cyc
1
F001
---
1
F300
---
1
F109
---
1
F102
DEFAULT
200
85
0
0 (Disabled)
0 (SRC 1)
0
30
700
0 (No)
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
0 (Voltage)
75
90
50
90
50
0 (Self-reset)
0
0 (Disabled)
0
63
0
0 (Disabled)
0 (SRC 1)
0
0
0
0
1000
0
0 (Self-reset)
0 (Disabled)