B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 26 of 74)
ADDR
REGISTER NAME
432C
...Repeated for User-Programmable LED 37
432F
...Repeated for User-Programmable LED 38
4332
...Repeated for User-Programmable LED 39
4335
...Repeated for User-Programmable LED 40
4338
...Repeated for User-Programmable LED 41
B
433B
...Repeated for User-Programmable LED 42
433E
...Repeated for User-Programmable LED 43
4341
...Repeated for User-Programmable LED 44
4344
...Repeated for User-Programmable LED 45
4347
...Repeated for User-Programmable LED 46
434A
...Repeated for User-Programmable LED 47
434D
...Repeated for User-Programmable LED 48
PRP Status (Read Only)
4363
Total Received Port A
4365
Total Received Port B
4367
Total Mismatches Port A
4369
Total Mismatches Port B
436B
Total Errors
IPv4 Route Table (Read/Write Setting) (6 Modules)
4370
IPv4 Network Route 1 Destination
4372
IPv4 Network Route 1 Netmask
4374
IPv4 Network Route 1 Gateway
4376
...Repeated for Route 2
437C
...Repeated for Route 3
4382
...Repeated for Route 4
4388
...Repeated for Route 5
438E
...Repeated for Route 6
Installation (Read/Write Setting)
43E0
Relay Programmed State
43E1
Relay Name
User Programmable Self Tests (Read/Write Setting)
4441
User Programmable Detect Ring Break Function
4442
User Programmable Direct Device Off Function
4443
User Programmable Remote Device Off Function
4444
User Programmable First Ethernet Fail Function
4445
User Programmable Secondary Ethernet Fail Function
4446
User Programmable Battery Fail Function
4447
User Programmable SNTP Fail Function
4448
User Programmable IRIG-B Fail Function
444A
Process Bus Failure Operand
444C
PTP Fail Function
444D
User Programmable Third Ethernet Fail Function
444E
User Programmable SFP Fail Function
CT Settings (Read/Write Setting) (6 Modules)
4480
Phase CT 1 Primary
4481
Phase CT 1 Secondary
4482
Ground CT 1 Primary
4483
Ground CT 1 Secondary
4484
...Repeated for CT Bank 2
4488
...Repeated for CT Bank 3
448C
...Repeated for CT Bank 4
4490
...Repeated for CT Bank 5
4494
...Repeated for CT Bank 6
B-34
RANGE
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 1
---
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 4294967295
0 to 1
0 to 1
0 to 1
1 to 65000
0 to 1
1 to 65000
0 to 1
T60 Transformer Protection System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F003
---
1
F133
---
---
F202
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F300
---
1
F102
---
1
F102
---
1
F102
A
1
F001
---
1
F123
A
1
F001
---
1
F123
DEFAULT
0
0
0
0
0
56554706
56554706
56554706
0 (Not
Programmed)
"Relay-1"
1 (Enabled)
1 (Enabled)
1 (Enabled)
0 (Disabled)
0 (Disabled)
1 (Enabled)
1 (Enabled)
1 (Enabled)
0
1 (Enabled)
0 (Disabled)
0 (Disabled)
1
0 (1 A)
1
0 (1 A)