Connecting The Lamp Power Supply - Christie Roadie 4K35 Quick Start Manual

High-brightness projection system
Hide thumbs Also See for Roadie 4K35:
Table of Contents

Advertisement

Connecting the lamp power supply

Connect the lamp power supply to the projector head.
Warning! Failure to comply with the following could result in death or serious injury.
A certified electrician must be present during installation.
Always connect the ground first to reduce shock hazard.
Do not return the current through the ground.
Use an appropriately sized strain relief connector with the knockout plate provided, to ensure
adequate environmental sealing and to prevent the AC supply cable from accidentally being torn
out or rubbing against the knockout plate.
Notice. Failure to comply with the following may result in property damage.
Incorrect lamp power supply and igniter connections can damage the product.
To avoid cross connections between projectors and lamp power supplies, always perform this
procedure in its entirety for each projector, one after another. Never attempt to connect multiple
projectors and lamp power supplies together at the same time.
1. Ensure the power is disconnected from the lamp power supply (LPS).
2. Electrician wiring—AC input:
Caution! Failure to comply with the following could result in minor or moderate injury.
a) Loosen the six screws to remove the LPS side panel.
b) Connect the AC directly to the LPS AC input terminal block according to your region.
For North America, Japan, Korea and most of Central/South America (200-230
VAC): Wire Phase 1, 2, 3 and Ground
For Europe and China (380-415 VAC): Wire Phase 1, 2, 3, Neutral and Ground
c) Move the AC input line voltage switch in the upper-left corner of the LPS to the left
when using a 200 VAC supply (on page 19), or to the right when using a 400 VAC
supply (on page 20).
Roadie 4K35 Quick Start Guide
020-101671-04 Rev. 1 (01-2016)
Copyright
2016 Christie Digital Systems USA Inc. All rights reserved.
©
Use an appropriately sized strain relief connector with the knockout plate provided to
ensure adequate environmental sealing and to prevent the cable from accidentally
being torn out.