Warning Threshold For Liquid Cooling Module; Touch Panel Controller; Power Requirements - Christie Roadie 4K35 Quick Start Manual

High-brightness projection system
Hide thumbs Also See for Roadie 4K35:
Table of Contents

Advertisement

Location
Liquid cooling pump (fan 14)
Igniter (fan 16)
IMCB (fan 18)
Red FPGA blower fan (fan 19)
Firewall fan (fan 20)

Warning threshold for liquid cooling module

Learn the warning thresholds (in RPMs) for the liquid cooling components.
Location
Flow meter
Liquid cooling pump

Touch panel controller

Review the specifications of the touch panel controller.
Touch panel controller 650H
Type of display
Display size
Display resolution (H x V pixels)
Maximum dimensions (W x H x D)
Integrated operating system
Communication interface with projector
Power requirement
Interface connector

Power requirements

Learn the power requirements for the projector.
Projection head
AC input
Rated input voltage
Rated line frequency
Inrush current
Roadie 4K35 Quick Start Guide
020-101671-04 Rev. 1 (01-2016)
Copyright
2016 Christie Digital Systems USA Inc. All rights reserved.
©
Warning RPM
No software feedback
6000
6000
4800
3300
Warning
0.2 mL/min
180 RPM
Color VGA TFT LCD, backlit
144.8 mm (5.7 inches) diagonal
640 x 480
195 mm x 148 mm x 58 mm
®
Microsoft Windows
XPe
10/100/1000 BaseT Ethernet
0.71A maximum at 24VDC ± 10%
12-pin circular connector (push-pull)
200 - 240 VAC
50 - 60 Hz nominal
70 A maximum
Specifications
38

Advertisement

Table of Contents
loading

Table of Contents