Christie Roadie 4K35 Quick Start Manual page 18

High-brightness projection system
Hide thumbs Also See for Roadie 4K35:
Table of Contents

Advertisement

d) Reinstall and secure the LPS side panel with six screws.
3. Connect the LPS communication cables:
a) Connect one end of the RS232 cable to the lower port on the LPS labeled RS232.
b) Connect one end of the Interlock cable to the upper port on the LPS labeled Interlock.
c) Connect the projector end of the cable to the port labeled RS232, located on the
connector box below the base of the projector on the lens side.
d) Connect the projector end of the Interlock cable to the port labeled Interlock, located
on the connector box below the base of the projector on the lens side.
4. Connect the DC lamp power cables:
Connect the negative (-) black lamp lead between the black connector (-) on the LPS and the
black connector (-) on the projector head. Connect the positive (+) red lamp lead between
the red connector (+) on the LPS and the red connector (+) on the projector head.
Reversing the connections can damage the projector.
When connecting DC cables between the ballast and the projector, be sure to fully connect
the cables and twist clockwise to ensure full engagement.
5. Connect one end of the line cord into the LPS power connector labeled Projector ONLY.
If using the longer DC cable kits, the projector head must be powered separately using
Christie recommended line cord provided for your region.
6. Connect the other end of the projector line cord into the plug on the bottom lamp-side of the
projector front bezel.
These connectors are controlled with the power connector breaker. For details, see the
interconnect drawing provided with the projector.
Warning! Failure to comply with the following could result in death or serious injury.
7. Verify the LPS to projector connections by making sure that all cables connected to the LPS
are connected to the same projector.
Roadie 4K35 Quick Start Guide
020-101671-04 Rev. 1 (01-2016)
Copyright
2016 Christie Digital Systems USA Inc. All rights reserved.
©
Notice. Failure to comply with the following may result in property damage.
SHOCK HAZARD! Internal input line voltage switch setting must match AC
available on site.
The power connector terminal block must be terminated correctly to allow 200 - 240
VAC output.
Do not access the product power directly from the building electrical source.
Installation and Setup