Func. Keys
:
:
:
:
(Fig. 48)
Fisch Food
Mode: Time
Max Time: 5m10s
Ascent Pump
UP01
A
B
(Fig. 49)
Lights Off
Mode: Switch
Light Hqi
UP01
A
B
(Fig. 50)
Manual top-up
Mode: Key
Top-up Pump
UP01
A
B
(Fig. 51)
36 - 60
Function Key Menu
This menu allows you to assign a function to every arrow key
on the controller.
Once the desired function has been programmed, press the
relative arrow for two seconds to enable the function.
A Function Key can be enabled only from the main screen, in
which the icon will appear
of an enabled function keys program.
To assign a function to an arrow key, proceed as follows:
Main display Main menu Func. keys Select
arrow key
To program a function key, proceed as follows:
• Use the keys to position yourself on the arrow you
wish to program and press "Enter" (Fig.48).
To enter the name of the function you wish to assign to the selected
key, select the letters by acting on the keys and act on the vu
keys to move around within the word. When you have finished, press
"Enter".
• Select the type of function you wish to assign to the key using
The functions will scroll down in the following order:
C
D
E
F
Off Time Switch Hold.
OFF FUNCTION: Function disabled.
TIME FUNCTION: Allows a function enablement time to be
established. Once enabled, the function remains on for the
preset time (Fig.49).
SWITCH FUNCTION: Allows the function assigned to the key
to be enabled and disabled manually (Fig.50). Every time the
C
D
E
F
key is pressed (for about 2 seconds), the function is enabled
or disabled depending on its status.
FUNCTION: "BUTTON" Allows the function assigned to the
button to be enabled only while the relative key is pressed
(Fig. 51).
Subsequently program the outlets on which the function
is to be enabled. Select the desired output with the keys
whereas change their status with the keys press
C
D
E
F
"Enter".
IsACQ110C-0 (ENG) Rev.230708-0
which will indicate the presence
.