Power Unit Menu
BLACKOUT
This function allows you to select which outlets you want to
stay disabled when the power supply is restored (after there
has been a blackout which lasts for longer than the time set
by the user) until they are automatically re-enabled after a
programmable time (Fig. 44).
To assign a blackout function to an outlet, proceed as fol-
lows:
Main screen Main menu Power unit Select
power unit Blackout Select outlet
•
Set the type of program to YES. (If it is left on NO, the
program will not be valid).
•
Set the Blackout duration time after which the controller
will automatically lock the outlet (Fig. 45).
•
Set a delay time, that is a time during which the outlet
stays disabled after the power supply has been restored (Fig.
45).
Unblock All (Fig. 46)
This unblocks all the deactivated outputs simultaneously when
a power outage has occurred for over an hour.
NOTE: this function is activated only if the power has
been interrupted for more than an hour.
To carry out this function, proceed as follows:
Main screen Main Menu Power Unit Power Cut
Unblock All.