Running Auto Calibrate

You can initiate Run Auto-Cal (Auto Calibrate) via the the SENSOR SETUP
menu.
NOTE: Verify that the Gap/Mark Sensor option (Gap, Mark, or Disable)
1. Press
2. Press Down +
displays.
3. Press the Right key until SENSOR SETUP displays.
4. Press
5. Press Down key until Run Auto-Cal displays.
6. Press
the label length indicators and then stops at the Top-of-Form position.
The Sensed Distance value will then display for one second.
7. Auto Calibrate is successful when the Sensed Distance value correctly
matches that of the installed media:
If "GAP NOT DETECTED" displays, run auto calibrate again.
If auto calibrate continues to end with an incorrect Sensed Distance value
displayed or a fault message displayed, run Manual Calibrate as
described on page 50 or see Table 15 on page 178.
matches the installed media. See "Sensing Different Media Types" on
page 46.
Check that the media sensors are horizontally positioned to permit
sensing of the label length indicators. See "Positioning The Media
Sensors" on page 44.
If Use Label Length is enabled in the SENSOR SETUP menu, make
sure the Label Length value entered in the MEDIA SETUP menu
matches the physical length of the installed media. Entering the
correct length forces the printer to advance media far enough during
calibrate for long labels (so actual gaps and marks can be detected)
and reduce the amount of media advanced for short labels.
If you try to do an Auto Calibrate when Peel-Off Media Handling is
enabled, the LCD will display "CANNOT CALIBRATE/Disable Peel-
Off." Before you can do an Auto Calibrate, you must select another
media handling mode or enable the Cal in Peel mode option under
the SENSOR SETUP menu. Cal in Peel Mode displays only if Admin
User is Enabled under the PRINTER SETUP menu.
. .
to place the printer in Menu mode.
.
(Enter) keys together until "THE
to enter the SENSOR SETUP menu.
to select the option. Media advances until it can accurately detect
Gap/Mark Sensor = Gap: The Sensed Distance value is the physical
length of one label plus the length of one gap, notch, or hole.
Gap/Mark Sensor = Mark: The Sensed Distance value is the
physical distance from the leading edge of one black mark to the
leading edge of the next.
Gap/Mark Sensor = Disable: Not applicable. If Gap/Mark Sensor is
set to Disable, the Sensed Distance value will not be updated.
Running Auto Calibrate
Sensing Different Media Types
KEY IS UNLOCKED"
47