ETHA1250
While operating the components, check whether the
operations are normal with timing chart.
ETACS FUNCTION
1.
Vehicle speed sensing intermittent wiper
Time specification
T1 : Max. 0.6 sec.
BODY ELECTRICAL SYSTEM
IGNSW
~~F~
L
WASHER
OFF
SW
ON
I
I
~ ~
WIPER
ON
L-.
OUTPUT
OFF
ETHA115D
3.
Rear window defogger
Time specification
T1 : 20±1 min.
T2 : 0.6-0.7 sec. (Time of wiper motor 1 rotation)
T3 : At vehicle speed = Okm/h.
2.6±0.7 sec. (VR=Okn)-18.0±1 sec (VR=50Kn)
At vehicle speed = 100km/h or more.
1.0±0.2sec (VR=Okn)-1 O.O±1 sec (VR=50Kn)
AlT"l"
DEFOGGER
ON
SW
OFF
DEFOGGER
ON
OUTPUT
OFF
L
ETHA115E
IGNSW
ON
~
OFF
LJ
L
4.
Seat belt warning
Time specification
INT
ON
WIPER
OFF
SW
INT
ON
WIPER
OFF
MOTOR
~.I
ETHA115C
T1 : 6 ± 1 sec.
T2 : 0.45±0.1 sec.
T3 : 0.3 ± 0.1 sec.
2.
Washer
a.
Time specification
T1 : 0.6 sec. or more
T2 : 2.5 - 3.8 sec.
T1 : 0.2 - 0.6 sec. (Mist)
b.
This function should be operated preferentially
even though the variable intermittent wiper is
operating.
IGNSW
SEAT BELT
SW(N/C)
CHIME
BEll
SIBElT
WARN'G
IND
~
ON
OFF
.
,
O N ,
I
OFF
ETHA115F
5.
Ignition key hole illumination
Time specification
T1 : 10 ± 1 sec.
T2 : 0 - 10 sec.