Service Specifications - Hyundai trajet Shop Manual

Table of Contents

Advertisement

GENERAL
BE-3
SERVICE SPECIFICATIONS
ETHA0050
Items
Specifications
Speedometer
Type
0
Cross coil type.
Input spec.
0
Hall IC type: 4 pulses/rev.
Indication
0
Km : At 637 rpm x 4 pulses/rev. indicate 60 Km/h
0
MILE: At 1026 rpm x 4 pulses/rev. indicate 60 MPH
Standard values
Velocity (KmI h)
20
40
60
80
100
120
Tolerance (KmI h)
20-24.1
40-43
60-64.1
80-85.2
100-105.2
120.5-126.3
Tolerance (KmI h)
20.8-25.4
40-44
60.8-65.4
81.4-86.8
102.6-108.2
123.5-129.6
Velocity (Kmi h)
140
160
180
200
Remarks
Tolerance (KmJ h)
140.5-146.7
160.5-167.5
181-188.4
201-209.1
EXCEPT, EEC & GENERAL
Tolerance (Km/h)
144.4-151
165.4-172.4 186.3-193.8 207.2-215.2
EEC, GENERAL
Velocity (MPH)
10
20
40
60
80
100
Tolerance (MPH)
10-12.5
20-22
40-42.6
60-63.4
80.3-84.1
100.3-104.7
Tolerance (MPH)
8.5-11.5
18.5-21.5
38.5-41.5
58.3-61.7
78-82
97.7-102.3
Velocity (MPH)
120
Remarks
Tolerance (MPH)
120.3-125.3
EXCEPT USA
Tolerance (MPH)
117.5-122.5
USA
0
Must tap the speedometer with hand to prevent hysterisis effects when inspected.
Tachometer
Type
0
Cross coil type. (4 cyl: 2pulses/ rev, 6 cyl: 3pulses/ rev)
Standard values
Revolution(RPM)
1000
2,000
3,000
4,000
5,000
6,000
7,000
Tolerance(RPM)
±100
±125
±150
±200
±250
±300
±350
0
Must tap the tachometer with hand to prevent hysterisis effects when inspected.
Fuel gauge
Type
a
Cross coil type (Fixed point type: Pointer should not fall into the "E" point but indicate
remaining fuel level when IG. off).
Gauge
Tolerance assembled
Standard values
Level
Resistance (0)
wnhfuel sender (0)
E (Empty)
95
40
+2.4
-
-2.2
1/2
32.5
O±5.3
F (Full)
7
40±3.5
0
Inspection order :
E~ F~
E
The indications must be read at least 7 minutes after the input of the datum resistance
value to each measuring point.
0
Point stabilty tolerance: Within 9°
Apply the power for 10 minutes. Then turn off the power source for 30 minutes and
read the position of the pointer.
ETHAO05A