Performing Initial Configuration
Related links
Configuring Ports on All Models of the Scopia
Configuring the UDP Port for the Gatekeeper on the Scopia
MCU
About this task
®
The Scopia
Elite 6000 Series MCU has designated port 1719 for gatekeeper use. You can
configure a different port to enable communication with the gatekeeper (for example, if port 1719 is
busy). Port 1719 is also used for RAS (to configure the UDP port for RAS, see
Port for RAS on the Scopia
Important:
If you close port 1719, you must configure another port for both the gatekeeper and RAS. If you
configure a different port for the gatekeeper, you do not need to configure a different port for
RAS.
Procedure
1. Navigate to the MCU H.323 Protocol section by selecting Configuration > Protocols.
2. Locate the Enable H.323 protocol section
Protocols tab
3. Enter the port value in the Gatekeeper port field.
4. Select Apply.
Related links
Configuring Ports on All Models of the Scopia
Configuring the TCP Port Q.931 on the Scopia
About this task
®
The Scopia
Elite 6000 Series MCU has designated port 1720 for Q.931. You can configure a
different port to use Q.931 (for example, if port 1720 is busy). Q.931 is a telephony protocol used for
establishing and terminating the connections in H.323 calls.
February 2016
®

Elite MCU

on page 69).
on page 70).
Figure 47: H.323 Protocol section of the Protocols tab
®
Avaya Scopia
Elite 6000 Series MCU Installation Guide
Comments on this document? infodev@avaya.com
®
Elite MCU
on page 65
(Figure 47: H.323 Protocol section of the
®