Cal Aftertouch - Behringer DEEPMIND 12 User Manual

Hide thumbs Also See for DEEPMIND 12:
Table of Contents

Advertisement

32
DeepMind 12 User Manual
Then move the PITCH WHEEL to its maximum position (shown on the panel).
You will see the following display showing the maximum position of the PITCH
WHEEL and the associated values:
Then move the PITCH WHEEL to its minimum position (shown on the panel).
You will see the following display showing the maximum position of the PITCH
WHEEL and the associated values:
To confi rm the CALIBRATION of the PITCH WHEEL press the +/YES switch and you
will be moved on to the PITCH CENTRE page:
At this point move the PITCH WHEEL within the dead zone where you don't feel
the tension of the spring. This is ensure that no pitch information is sent while the
pitch wheel is not being touched. You will see the following display showing a
guide to assist you:
Note: To cancel the routine you can press the -/NO switch.
To confi rm the CALIBRATION of the PITCH CENTRE press the +/YES switch: The
calibration data will then be stored for the PITCH CENTRE and you will be returned
to the CALIBRATE menu. From here you can perform another calibration from the
menu, or press the GLOBAL switch again to return to the SYSTEM SETTINGS menu.

CAL AFTERTOUCH

To calibrate the KEYBOARD AFTERTOUCH please use the following process:
Note: During the calibration the GLOBAL, -NO and +/YES switches will be
fl ashing. If at any time you want to cancel the calibration routine, you can press
the -/NO switch. No previous calibration data will be changed if you do cancel the
routine. To confi rm the calibration at each stage press +/YES as described below.
In order to start the calibration routine make sure that the ' < ' symbol on the CAL
AFTERTOUCH line is highlighted and press +/YES.
You will see the following display showing a bar representing the current
AFTERTOUCH value (0% for no pressure). Also on this screen you can see the
stored calibration data above the bar and the current value below the bar:
Then apply pressure to any one of the keys (or multiple keys) until the value stops
increasing.
You will see the following display showing the maximum position of the
AFTERTOUCH and the associated value:
Note: To cancel the routine you can press the -/NO switch.
To confi rm the CALIBRATION of the AFTERTOUCH press the +/YES switch: The
calibration data will then be stored for the AFTERTOUCH and you will be returned
to the CALIBRATE menu. From here you can perform another calibration from the
menu, or press the GLOBAL switch again to return to the SYSTEM SETTINGS menu.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents