CP-Parameter
4.3

Parameter description for F5 servo

Display Parameter
CP.00 Password input
CP.01 Encoder 1 speed
CP.02 Setpoint display
CP.03 Inverter state
CP.04 Apparent current
CP.05 Apparent current / peak value
CP.06 Actual torque display
CP.07 DC-link voltage
CP.08 DC-link voltage / peak value
CP.09 Output voltage
CP.10 Speed control configuration
CP.11 DSM rated torque
CP.12 DSM rated speed
CP.13 DSM rated frequency
CP.14 DSM rated current
CP.15 DSM EMK voltage constant
CP.16 DSM winding inductance
CP.17 DSM winding resistance
CP.18 DSM current for zero speed
CP.19 Load motor dependent parameter
CP.20 Absolute position enc.1
CP.21 Encoder 1 rotation
CP.22 max. reference forward
CP.23 Step value 1
CP.24 Step value 2
CP.25 Acceleration time
CP.26 Deceleration time
CP.27 S-curve time
CP.28 Torque reference source
CP.29 Abs. torque reference
CP.30 KP speed
CP.31 KI speed
CP.32 Switching frequency
CP.33 Relay output 1 / function
CP.34 Relay output 2 / function
CP.35 Limit switch / stopping mode
CP.36 External Fault / stopping mode
CP.3
Inverter state
In parameter „inverter status" the actual operating condition of the frequency inverter
is displayed. In the case of an error the current error message is displayed, even if the
display has already been reset with ENTER (error-LED on the operator is still blinking).
Status messages and information about the cause and removal are to be found in www.
keb.de => Documentation => Operating Instructions => Other => Service informations =>
Error and status messages.doc.
GB - 80
Setting Range
Resolution Default
0...9999
±4000
0.125
±4000
0.125
0...255
0...6553.5
0.1
0...6553.5
0.1
±10000.00
0.01
0...1000
0...1000
0...778
4...6
0.1...6553.5
0.1
0...32000
0.0...1600.0
0.1
0.0...710.0
0.1
0...1000
0.01...500.00
0.01
0.000...50.000
0.001
0.0...700.0
0.1
0...3
0...65535
0...19
0...4000
0.125
±4000
0.125
±4000
0.125
0.00...300.00
0.01
-0.01...300.00
0.01
0.00...5.00
0.01
0...5
±10000.00
0.01
0...32767
0...32767
0...LTK
0...78
0...78
0...6
0...6
Unit ENTER Based on
1
-
-
0
rpm
0
rpm
1
0
-
0
A
0
A
0
Nm
1
0
V
1
0
V
1
0
V
1
4
-
LTK
Nm
1
LTK
rpm
LTK
Hz
LTK
A
1
LTK
V
LTK
mH
LTK
LTK
A
1
1
-
1
57057
-
1
0
-
2100
rpm
100
rpm
-100
rpm
5
s
5
s
0
s
1
2
-
LTK
Nm
1
50
-
1
500
-
1
LTK
-
1
4
-
1
2
-
1
6
-
1
0
-
-
ud.01
-
ru.09
-
ru.01
-
ru.00
-
ru.15
-
ru.16
-
ru.12
-
ru.18
-
ru.19
-
ru.20
-
cs.00
-
dr.27
-
dr.24
-
dr.25
-
dr.23
-
dr.26
-
dr.31
-
dr.30
-
dr.28
E
fr.10
-
ec.02
-
ec.06
-
op.10
-
op.21
-
op.22
-
op.28
-
op.30
-
op.32
E
cs.15
-
cs.19
-
cs.06
-
cs.09
E
uf.11
E
do.2
E
do.3
-
pn.7
-
pn.3