Resetting Error Messages; Password Input - KEB COMBIVERT F5 Installation Manual

Digital servo controller
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

4.2.2

Resetting error messages

If a malfunction occurs during operation, then the actual display is overwritten by the alarm
message. The alarm message in the display is reset by ENTER.
With ENTER only the error message in the display is reset. In order to reset
the error itself, the cause must be removed or a power-on reset must be made.
4.2.3

Password Input

The KEB COMBIVERT is outfitted with a comprehensive password protection. In dependence
on the entered password the following modes are possible:
Display Mode
CP_ro
CP_on
CP_SE Service menu (like end customer menu, but with the original parameters )
APPL
The menu admissible for the application is defined by the machine builder. The password
input is generally made over the parameter CP.0. The adjusted password/menu is maintained
even after switching off.
Example: Changing the CP-parameter from read-only to read/write
— Error —>
End customer menu (CP-Parameter) read-only
End customer menu (CP-Parameter) read/write
Application menu (all parameter groups and parameters are visible)
Drive mode (COMBIVERT can be put into operation by the keyboard )
FUNC
Operation of the Unit
ENTER
Password
UP
ENTER
F/R
GB - 69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents