[SwitchC-pim6] bidir-pim enable
# On Switch D, enable IPv6 multicast routing, enable IPv6 PIM-SM on each interface, enable MLD on
VLAN interface 300, and enable IPv6 BIDIR-PIM.
<SwitchD> system-view
[SwitchD] multicast ipv6 routing-enable
[SwitchD] interface vlan-interface 300
[SwitchD-Vlan-interface300] mld enable
[SwitchD-Vlan-interface300] pim ipv6 sm
[SwitchD-Vlan-interface300] quit
[SwitchD] interface vlan-interface 400
[SwitchD-Vlan-interface400] pim ipv6 sm
[SwitchD-Vlan-interface400] quit
[SwitchD] interface vlan-interface 103
[SwitchD-Vlan-interface103] pim ipv6 sm
[SwitchD-Vlan-interface103] quit
[SwitchD] pim ipv6
[SwitchD-pim6] bidir-pim enable
[SwitchD-pim6] quit
Configure C-BSR and C-RP.
3.
# On Switch C, configure VLAN interface 102 as a C-BSR, and loopback interface 0 as a C-RP for the
entire IPv6 BIDIR-PIM domain.
[SwitchC-pim6] c-bsr 2002::2
[SwitchC-pim6] c-rp 6001::1 bidir
[SwitchC-pim6] quit
Verify the configuration.
4.
To view the DF information of IPv6 BIDIR-PIM on a switch, use the display pim ipv6 df-info command:
# View the DF information of IPv6 BIDIR-PIM on Switch A.
[SwitchA] display pim ipv6 df-info
RP Address: 6001::1
Interface
Vlan100
Vlan101
# View the DF information of IPv6 BIDIR-PIM on Switch B.
[SwitchB] display pim ipv6 df-info
RP Address: 6001::1
Interface
Vlan200
Vlan101
Vlan102
# View the DF information of IPv6 BIDIR-PIM on Switch C.
State
DF-Pref
DF-Metric
Win
100
2
Lose
100
1
State
DF-Pref
DF-Metric
Win
100
1
Win
100
1
Lose
0
0
398
DF-Uptime DF-Address
01:08:50
FE80::200:5EFF:
FE71:2800 (local)
01:07:49
FE80::20F:E2FF:
FE38:4E01
DF-Uptime DF-Address
01:24:09
FE80::200:5EFF:
FE71:2801 (local)
01:24:09
FE80::20F:E2FF:
FE38:4E01 (local)
01:23:12
FE80::20F:E2FF:
FE15:5601