HP A5500 SI Switch Series Configuration Manual page 215

Hide thumbs Also See for A5500 SI Switch Series:
Table of Contents

Advertisement

Each PIM-SM domain has zero or one multicast source and receiver. OSPF runs within each
domain to provide unicast routes.
Loopback 0 of Switch B, Switch C, and Switch E must be configured as the C-BSR and C-RP of the
PIM-SM domains respectively.
An MSDP peering relationship must be set up between Switch B and Switch C through eBGP, and
between Switch C and Switch E through iBGP.
Figure 58 Network diagram for inter-AS multicast configuration leveraging BGP routes
Device
Switch A
Switch B
Switch C
Configuration procedure
Configure IP addresses and unicast routing
1.
Configure the IP address and subnet mask for each interface according to
Configure OSPF for interconnection between switches in each AS. Ensure the network-layer
interoperation among each AS, and ensure the dynamic update of routing information between the
switches through a unicast routing protocol (details not shown).
Enable IP multicast routing, enable PIM-SM on each interface, and configure a PIM-SM domain
2.
border
Interface
IP address
Vlan-int103
10.110.1.2/24
Vlan-int100
10.110.2.1/24
Vlan-int200
10.110.3.1/24
Vlan-int103
10.110.1.1/24
Vlan-int101
192.168.1.1/24
Loop0
1.1.1.1/32
Vlan-int104
10.110.4.1/24
Vlan-int102
192.168.3.1/24
Vlan-int101
192.168.1.2/24
Loop0
2.2.2.2/32
Device
Interface
Switch D
Vlan-int104
Vlan-int300
Switch E
Vlan-int105
Vlan-int102
Loop0
Switch F
Vlan-int105
Vlan-int400
Source 1
Source 2
203
IP address
10.110.4.2/24
10.110.5.1/24
10.110.6.1/24
192.168.3.2/24
3.3.3.3/32
10.110.6.2/24
10.110.7.1/24
10.110.2.100/24
10.110.5.100/24
Figure 58
(details not shown).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A5500 ei switch series

Table of Contents