General Specifications And Troubleshooting; Mains Supply Tables - Danfoss FC 102 Design Manual

1.1-90 kw
Hide thumbs Also See for FC 102:
Table of Contents

Advertisement

General Specifications and ...

9 General Specifications and Troubleshooting

9.1 Mains Supply Tables

Mains supply 3x200-240 V AC - Normal overload 110% for 1 minute
Frequency Converter
Typical Shaft Output [kW]
IP20/Chassis
(A2+A3 may be converted to IP21 using a conversion kit)
IP55/NEMA 12
IP66/NEMA 12
Typical Shaft Output [hp] at 208 V
Output current
Continuous
(3x200-240 V) [A]
Intermittent
(3x200-240 V) [A]
Continuous
kVA (208 V AC) [kVA]
Max. cable size:
(mains, motor, brake)
[mm
Max. input current
Continuous
(3x200-240 V) [A]
Intermittent
(3x200-240 V) [A]
Max. pre-fuses
Environment
Estimated power loss
at rated max. load [W]
Weight enclosure IP20 [kg]
Weight enclosure IP21 [kg]
Weight enclosure IP55 [kg]
Weight enclosure IP66 [kg]
Efficiency
Table 9.1 Mains Supply 3x200-240 V AC
MG11BC02
Design Guide
2
/AWG]
2)
1)
[A]
4)
3)
Danfoss A/S © Rev. 06/2014 All rights reserved.
P1K1
P1K5
P2K2
1.1
1.5
2.2
A2
A2
A2
A4/A5
A4/A5
A4/A5
A5
A5
A5
1.5
2.0
2.9
6.6
7.5
10.6
7.3
8.3
11.7
2.38
2.70
3.82
4/10
5.9
6.8
9.5
6.5
7.5
10.5
20
20
20
63
82
116
4.9
4.9
4.9
5.5
5.5
5.5
9.7/13.5
9.7/13.5
9.7/13.5
9.7/13.5
9.7/13.5
9.7/13.5
0.96
0.96
0.96
P3K0
P3K7
3
3.7
A3
A3
A5
A5
A5
A5
4.0
4.9
12.5
16.7
13.8
18.4
4.50
6.00
9
11.3
15.0
12.4
16.5
32
32
155
185
6.6
6.6
7.5
7.5
13.5
13.5
13.5
13.5
0.96
0.96
147
9

Advertisement