Design and function
Transport and installation
5.1.6
Intermediate hose package connection
Some wire electrodes (e.g. self-shielding cored wire) are welded using negative polarity. In this
case, the welding current lead should be connected to the "-" welding current socket, and the
workpiece lead should be connected to the "+" welding current socket. Observe the information
from the electrode manufacturer!
Item Symbol
1
2
3
4
5
•
Insert the welding current cable plug into the relevant welding current connection socket and lock by
turning to the right:
MIG/MAG cored wire: Welding current "-" connection socket
MIG/MAG standard: Welding current "+" connection socket
•
Insert cable plug on the control lead into the 19-pole connection socket and secure with crown nut (the
plug can only be inserted into the connection socket in one position).
24
Description
0
Wire feed unit
Intermediate hose package
19-pole connection socket (analogue)
Wire feed unit control lead connection
Connection socket, "+" welding current
•
Standard MIG/MAG welding (intermediate hose package)
Connection socket, "-" welding current
•
MIG/MAG cored wire welding:
Figure 5-3
Welding current to wire feed/torch
099-005221-EW501
05.09.2016