8.2

Taurus 405 TDM

Setting range for welding current
Setting range for welding voltage
Duty cycle
100% DC
Load cycle
Open circuit voltage
Mains voltage (tolerances)
Frequency
Mains fuse (safety fuse, slow-blow)
Mains connection lead
Max. connected load
Recommended generator rating
cos/efficiency
Ambient temperature
Machine cooling/torch cooling
Workpiece lead
Insulation class/protection classification
EMC class
Safety identification
Other standards used
Dimensions (L x W x H)
Weight
099-005221-EW501
05.09.2016
MIG/MAG
5 A–400 A
14.3 V–34.0 V
40 °C
400 A
10 min. (60% DC
6 min. welding, 4 min. pause)
79 V
3 x 400 V (-25% to +20%)
50/60 Hz
3 x 32 A
H07RN-F4G6
17.2 kVA
24.6 kVA
0.99/90%
-25 C to +40 C
Fan (AF)/gas
70 mm
H/IP 23
A
/
IEC 60974-1, -10
625 mm x 298 mm x 531 mm
24.6 inch x 11.7 inch x 20.9 inch
41 kg
90.4 lb
Technical data
Taurus 405 TDM
MMA
20.2 V–36.0 V
18.2 kVA
2
/