Welding data display
The machine control displays show all welding parameters that are required by the welder. The lower
centre display shows the selected welding task (JOB number). The "parameter selection" (
button can be used to switch the display between welding voltage, welding performance and gas flow rate
(option).
What is shown on the displays depends, among other things, on the selected welding procedure and the
machine state (welding, power-saving mode, machine error).
MIG/MAG welding
Parameter
Welding current
Wire feed speed
Welding voltage
Welding performance
MMA welding
Parameter
Welding current
Welding voltage
Welding performance
099-005221-EW501
05.09.2016
Figure 5-12
Nominal values
Actual values
Nominal values
Actual values
Design and function
Hold values
Hold values
Welding data display