Machine Configuration Menu; Selecting, Changing And Saving Parameters - EWM TAURUS 355 Basic TDM Operating Instruction

Hide thumbs Also See for TAURUS 355 Basic TDM:
Table of Contents

Advertisement

Design and function

Machine configuration menu

5.6
Machine configuration menu
5.6.1

Selecting, changing and saving parameters

ENTER (Enter the menu)
Switch off the machine at the main switch.
Press and hold down the "Welding procedure" push-button and switch the machine on again
at the same time.
NAVIGATION (Navigate the menu)
Select parameters by turning the "Welding parameter setting" rotary knob.
Set or change the parameters by turning the "Welding voltage" rotary knob.
EXIT (Exit the menu)
Press the "Push-button, parameter selection right" push-button (switch machine off and on
again).
Enter
Display
44
0
l
Setting/selection
Lead resistance 1
Lead resistance for the first welding circuit 0 mΩ–60 mΩ (8 mΩ ex works).
Only qualified service personnel may change the parameters!
Time-controlled power-saving mode > see 5.6.2 chapter
• ---------- 5 min.–60 min. = time until activation of power-saving mode when inactive.
• ---------- off = switched off
Service menu
Modifications to the service menu may only be carried out by authorised maintenance
staff!
+
Figure 5-27