Tuning pump
Pressing buttons 4 and 5 it is possible to adjust the general flow of the water setting the parameters
"low", "medium", "medium-high" and "high".
At the end of programming, press button 1 to confirm the set data.
12.5.7 Reading of the sales data
This sub-menu concerns the reading of the sales data. The machine keeps various counters stored,
which allow a direct reading for consumption and cashing.
To have an immediate reading of all the data audit, simply press the key on the display board inside the
machine and then button 2.
The will display show:
1=PROG
3=FREE
2=DATA 4=CLEAN
5=MAINT.
And then all counters here under described will be displayed.
All counters, except that of total cycles, can be set to zero. To reset a counter, when it is visualised on
the display, keep pressed button 4. Do as follows:
press button 1 until the sub-menu
SALES DATA - - - - - -
- - - - - - - - - - - - - - - - -
is displayed.
Then press button 2 and the following counters are shown in sequence:
TOTAL SELECTIONS
This value indicates the total sale cycles of the machine. This value cannot be set to zero.
PARTIAL SELECTIONS
This value indicates the partial number of sale cycles of the machine starting from the last reset
operation.
TOTAL MONEY
This value indicates the amount of money cashed starting from the last reset operation.
low
XXXXXX
XXXXXX
XXXXXXXX
39