Panasonic KX-TDA50 Feature Manual page 241

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA50:
Table of Contents

Advertisement

It is only possible to assign NDSS buttons for extensions that have been previously registered in the
Network Monitor Extensions Table.
2.10.5 [4-1-4] Wired Extension—Flexible Button
→ Type
→ Dial (for NDSS)
2.10.13 [4-2-3] Portable Station—Flexible Button
→ Type
→ Dial (for NDSS)
2.10.17 [4-3] DSS Console—Flexible Button
→ Type
→ Dial (for NDSS)
Extensions connected to one PBX can monitor a maximum of 250 extensions at other PBXs. One
extension can be monitored by multiple extensions at multiple PBXs.
To reduce NDSS data traffic, it is recommended that 8 or less extensions in a single Incoming Call
Distribution Group be monitored.
Activation of an NDSS button is only required the first time that a button for a newly registered extension
is created. Once an NDSS button has been activated by being pressed the first time, any further NDSS
buttons for the same monitored extension will automatically display the extension status without
needing to be activated.
To use the NDSS Monitor Release feature, an extension must be assigned as a manager.
→ 2.8.11 [2-7-1] Class of Service—COS Settings—Extension Feature—Manager
→ [511] Manager Assignment
Through system programming, it is possible to assign a maximum number of "hops" (transfers between
PBXs) that extension status information can travel. Each time a piece of extension status information
is forwarded to another PBX, its counter is increased by one. When this counter reaches the assigned
maximum, the data is discarded. This is used to prevent data from circling unnecessarily around the
network.
→ 2.15.2 [9-2] Network Data Transmission—Network BLF Data Transmission for Centralized Operator
Feature—Data Transmission Counter
If it is not possible to remotely turn off transmission of extension status information using the NDSS
Monitor Release feature because of network conditions, it is possible to perform the same operation
directly through system programming at the monitored PBX.
→ 2.10.8 [4-1-6] Wired Extension—NDSS Link Data - Send
→ 2.10.15 [4-2-4] Portable Station—NDSS Link Data - Send
When using a VoIP network, if extension status information is lost by the network, in some cases an
NDSS button may not be able to display the status of the relevant extension.
NDSS can not be used when two PBXs are networked using the TIE Line Call by Own PBX Extension
Number feature (→ 1.13.13 PRIVATE NETWORK FEATURES).
Programming References
PC Programming Manual
2.7.14 [1-1] Slot—PRI Port (KX-TDA100/KX-TDA200/KX-TDA600 only)—CO Setting—Networking Data
Transfer
2.8.11 [2-7-1] Class of Service—COS Settings—Extension Feature—Manager
2.10.5 [4-1-4] Wired Extension—Flexible Button
→ Type
→ Dial (for NDSS)
2.10.8 [4-1-6] Wired Extension—NDSS Link Data - Send
2.10.13 [4-2-3] Portable Station—Flexible Button
→ Type
1.13 P
Feature Manual
241

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda200Kx-tda600Kx-tda100

Table of Contents